beautypg.com

Installation and external connection, Power, reader, and i/o connection, Power connection – Samsung SSA-P102T User Manual

Page 12: Reader connection, Dc +12v gnd

background image

12_

installation and external connection

installation and external connection

POWER, READER, AND I/O CONNECTION

Power Connection

Check the location of the power port.

- Connect the plus (+) line of DC 12V to the corresponding port (+12V).

- Connect the plus (-) line of DC 12V to the GND (-) port.

Reader Connection

- You can safely use other power sources for the reader than supplied from the specifi ed port; however, all

power sources should be connected to the common GND port. Failure of the GND grounding will cause a
transfer error of Wigand data to the controller due to a voltage difference.
Connect Wiegand Data Output 0 of the proximity reader to the D0 port and connect Wiegand Data Output
1 to the D1 port of P102(T).

X

Y

Z

[

\

]

^

_

`

lzj

lu{

W

iŒ““

X

Y

Z

[

\

]

^

_

`

lzj

lu{

W

iŒ““

READER #2

READER #1

BLACK

GND

WHITE

D1

GREEN

D0

RED

+12V

BLACK

GND

WHITE

D1

GREEN

D0

RED

+12V

DC +12V

GND