Figure : spa equipment compartment – Sundance Spas 850 Series User Manual
Page 15
1
Figure :
Spa equipment compartment
Control Box
TB1
TB1
Terminal
Ground/
Bonding Lug
Green
Note: TB1 terminal location will vary between models
Hot T
ub
Contr
ol Bo
x
TB1
White
(Neutral)
Red (L2)
Green
Black (L1)
Figure 6:
Control Box
Figure 7A:
Standard 3-wire, 120 VAC
connection for Denali, Metro,
Solo, Tacoma models. Use
the provided 10' GFCI cord (US
Only) or hard wire for runs over 10'
(3m) or for all Canadian models.
Figure 7B:
Optional 4-wire, 240/120 VAC
connection for Denali, Metro,
Solo, Tacoma models.
Move Red Wire to terminal
position #3 as shown.
(
Hard wired connections only).
To spa
circuit
To spa
circuit
To spa
circuit
White
(Neutral)
Black (L)
White
White
Black
Black
Red
Red
E
xt
e
rn
a
l
Po
w
e
r
E
xt
e
rn
a
l
Po
w
e
r
Power Supply Inlets