Ultra force, Other ultra force, Features – State Industries SUF 100 250NE User Manual
Page 2
ULTRA FORCE
™
UP TO 96% EFFICIENT COMMERCIAL GAS WATER HEATERS
C O M M E R C I A L
Other Ultra Force
™
Features:
Commercial Grade Glass-Lined Tank and
Heat Exchanger for Long-Term Protection
Against Corrosion
• Heat exchanger glass-lined on both water and vent sides to
protect against corrosive flue gases and condensate
Handhole Cleanout
• For easy inspection and cleaning
Meets ASHRAE/IES 90.1-Current Standard Requirements
• Also meets SCAQMD low-NOx Rule 1146.2
• Design-certified by CSA International, according to ANSZ21.10
storage-type water heater standards
Three-Year Limited Tank Warranty
• For complete warranty information, consult written warranty
shipped with water heater or contact State Water Heaters
U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED
MODEL
INPUT
Thermal
Efficiency
Approx.
Capacity
Fº
30 Fº
40 Fº
50 Fº
60 Fº
70 Fº
80 Fº
90 Fº
100 Fº 110 Fº 120 Fº 130 Fº 140 Fº
BTUH
KW
Cº
17 Cº
22 Cº
28 Cº
33 Cº
39 Cº
44 Cº
50 Cº
56 Cº
61 Cº
67 Cº
72 Cº
78 Cº
SUF 60
120NE
120,000
95%
60 U.S. Gals.
GPH
461
345
276
230
197
173
154
138
126
115
106
99
35
227 Litres
LPH
1744
1308
1046
872
747
654
581
523
476
436
402
374
95%
100 U.S. Gals.
GPH
576
432
345
288
247
216
192
173
157
144
133
123
44
379 Litres
LPH
2179
1635
1308
1090
934
817
726
654
594
545
503
467
95%
100 U.S. Gals.
GPH
767
575
460
384
329
288
256
230
209
192
177
164
58
379 Litres
LPH
2904
2178
1743
1452
1245
1089
968
871
792
726
670
622
95%
100 U.S. Gals.
GPH
960
720
576
480
411
360
320
276
262
240
221
206
73
379 Litres
LPH
3632
2724
2179
1816
1557
1362
1211
1044
991
908
838
778
96%
130 U.S. Gals.
GPH
1164
873
699
582
499
436
388
349
318
291
269
250
88
492 Litres
LPH
4406
3304
2644
2203
1888
1652
1469
1322
1201
1102
1017
945
96%
130 U.S. Gals.
GPH
1552
1164
931
776
665
582
517
465
423
388
359
332
117
492 Litres
LPH
5875
4406
3525
2938
2518
2203
1958
1750
1602
1469
1356
1259
TYPE OF
GAS
NATURAL/
PROPANE
NATURAL/
PROPANE
NATURAL/
PROPANE
NATURAL/
PROPANE
NATURAL/
PROPANE
NATURAL/
PROPANE
Recovery capacities are based on heater performance at 95% and 96% thermal efficiency.
Add “A” to model number when ordering ASME. Optional on SUF 60 120NE - SUF 100 250NE Models. Standard on SUF 130 300NEA and SUF 130 400NEA Models.
Maximum gas supply pressure for 120 - 250: 10.5˝ w.c. natural gas 14˝ w.c propane. Maximum gas supply pressure for 300-400 10˝ w.c. natural gas 13˝ w.c. propane.
Manifold pressure: 4˝ w.c. natural gas 10˝ w.c. propane. Electrical requirements: 120 VAC, Blower 2.2 Amps FL, Igniter 4.0 Amps.
RECOVERY CAPACITY
SUF 60 120NE - SUF 100 250NE Models
SUF 130 300NEA - SUF 130 400NEA Models
150,000
199,900
250,000
300,000
399,900
• Design-certified by Underwriters Laboratories Sanitation to NSF Standard
SUF 100
150NE
SUF 100
199NE
SUF 100
250NE
SUF 130
300NEA
SUF 130
400NEA
5 for 180
o
F (62
o
C) water
195810_SCGSS00207.indd 2
195810_SCGSS00207.indd 2
5/30/08 2:46:04 PM
5/30/08 2:46:04 PM