beautypg.com

2 burner and nozzle characteristics table, 3 arrangement of the burners on the hob, 1 auxiliary – Smeg SA92MFX5 User Manual

Page 20: 2 semi rapid, 3 rapid, 4 triple crown, Instructions for the installer

background image

Instructions for the installer

22

14.2 Burner and nozzle characteristics table

Burner

ULPG (PROPANE) – 2.75 kPa

Nominal gas

consumption

(MJ/h)

Turn-down gas

consumption

(MJ/h)

Injector

(mm)

Auxiliary

3.9

1.5

0.54

Semi rapid

6.3

1.5

0.68

Rapid

10.0

2.7

0.88

Triple crown

12.8

5.4

1.00

Burner

NG – 1.0 kPa

Nominal gas

consumption

(MJ/h)

Turn-down gas

consumption

(MJ/h)

Injector

(mm)

Auxiliary

3.9

1.5

0.90

Semi rapid

6.5

1.5

1.20

Rapid

12

2.7

1.55

Triple crown

15

5.4

1.75

14.3 Arrangement of the burners on the hob

BURNERS

1 Auxiliary

2 Semi rapid

3 Rapid

4 Triple crown

ø min e max (in cm.)

12 - 14

16 - 24

18 - 26

18 - 26