Replacing the Air Filter
Oth
e
rs
Check that the ON/STANDBY indicator
lights in red.
9
Point the remote control at the
projector and press the following
buttons on the remote control in
the following order for less than
five seconds each: RESET,
<,
,, ENTER.
• Do not put your hands into the lamp
replacement spot, or not fall any liquid or
object into it to avoid electrical shock or fire.
• Be sure to use the LMP-H130 Projector
Lamp for replacement. If you use lamps
other than LMP-H130, the projector may
cause a malfunction.
• Be sure to turn off the projector and unplug
the power cord before replacing the lamp.
• The projector will not turn on unless the lamp
is securely installed in place.
• The projector will not turn on unless the lamp
cover is securely closed.
• To erase the message displayed on the
screen, press any button on the remote
control or the control panel.
Disposal of the used lamp
For the customers in the USA
this product may be regulated if sold in the
United States. For disposal or recycling
information, please contact your local
authorities or Electronics Industries Alliance
(http://www.eiae.org).
Replacing the Air
Filter
The air filter should be replaced
periodically. When “Please replace the
filter.” appears on the screen, replace the air
filter immediately.
• Replacing the air filter is very important to
maintain the high efficiency of the projector
and to prevent a malfunction. When the
replacement message appears on the screen,
replace the air filter without delay. It is
recommended to replace the air filter
approximately every 1000 hours of use.
• When removing the air filter from the
projector, be careful that no dust or object
gets into the inside of the projector.
1
Turn off the projector, then
unplug the AC power cord.
2
Open the filter cover toward you,
while pushing the three filter lock
knobs upward.
3
Remove the air filter from the
projector by holding the tab on the
filter.
Notes
Notes