16

Constellation ES Serial ATA Product Manual, Rev. F

S.M.A.R.T. Read Data Reports

• Attribute 192 - Emergency Retract Count

• Attribute 193 - Load/Unload Cycle Count

PowerChoice Manufacture Default Power Condition Timer Values

Default power condition timer values have been established to assure product reliability and data integrity. A
minimum timer value threshold of two minutes ensures the appropriate amount of background drive mainte-
nance activities occur. Attempting to set a timer values less than the specified minimum timer value threshold
will result in an aborted EPC "Set Power Condition Timer" subcommand.

Setting power condition timer values less than the manufacturer specified defaults or issuing the EPC "Go to
Power Condition" subcommand at a rate exceeding the default timers may limit this products reliability and
data integrity.

PowerChoice Supported Extended Power Condition Feature Subcommands

EPC Subcommand

Description

00

H

Restore Power Condition Settings

01

H

Go to Power Condition

02

H

Set Power Condition Timer

03

H

Set Power Condition State

PowerChoice Supported Extended Power Condition Indentifiers

Power Condition Identifiers

Power Condition Name

00

H

Standby_z

01 - 80

H

Reserved

81

H

Idle_a

82

H

Idle_b

83

H

Idle_c

84 - FE

H

Reserved

FF

H

All EPC Power Conditions

Power Condition Name

Manufacturer Default Timer Values

Idle_a

2 min

Idle_b

4 min

Idle_c

10 min

Standby_z

15 min