Cv-m10bx/cv-m10rs, Timing diagram for edge pre-select – JAI CV-M10 User Manual
Page 9
- 6 -
CV-M10BX/CV-M10RS
The resulting video signal will start to be read out after the trigger rising edge. The WEN pulse indicates the start of valid
video signal. Refer to timing charts for details.
A new trigger pulse must not be applied before the video read out has been finished.
To use this mode:
Set:
SW1-4 on BX rear to OFF for random trigger. For RS select trigger mode
JP12 on PK8206 (BX ver.) or PK8190 (RS ver.) Short for Pulse Width Control
JP13 on PK8206 (BX ver.) or PK8190 (RS ver.) OPEN for H Reset
JP13 on PK8206 (BX ver.) or PK8190 (RS ver.) Short for H Non Reset
SW1-1 through SW1-3 on BX rear to ON (1/10,000) For RS select 1/10,000
and SW1 on (BX) PK8206 for Normal shutter.
Note:
For CV-M10RS the selection of Edge Pre-select, Pulse Width Control H Reset and H non-reset cannot be done by
RS232C. In Pulse Width Control Mode the shutter speed must be set at 1/10000 sec.
(See chapter 7 and 8 for details)
6.4. Timing diagram for Edge Pre-select
TRIG
XSUB
XSG
WEN
VIDEO 1
VIDEO 2
VIDEO 1
2:1 interlace in field accumulation
Non interlace in frame accumulation
7HD
EIA:247HD CCIR:291HD
14HD
EIA:494HD CCIR:582HD
exposure time
Edge pre select mode (H reset)
HD RESET
INT HD
TRIG
EXT ED
XSUB
XSG
WEN
VIDEO 1
2:1 interlace in field accumulation
VIDEO 2
VIDEO 1
Non interlace in frame accumulation
7HD
EIA:247HD CCIR:291HD
14HD
EIA:494HD CCIR:582HD
Edge pre select mode (H Non Reset)
exposure time