JAI IIT Camera Systems VIS-CAM 400 User Manual
Page 42

IIT Camera System Manual
 
 
42
Appendix G
5
Connect the camera to
the Ethernet port of an 
appropriate test PC. 
Switch on the camera 
power. Launch EN Setup 
application 
 
Sec. 4
6
Align camera
mechanically to correct 
position by adjusting 
the VIS Mount and using 
the tools from EN 
Setup.
Do not adjust
the camera mount
inside the housing.
Sec. 4
7
Focus lens and make 
sure that the lens iris is 
fully open and no 
polarizer is mounted. 
Secure locking screws 
after adjustment 
Appendix B
8
Properties settings using 
internal Light Sensor: 
 
 
Sec. 4.1
(IIT IO Board settings: X=05, Y=0A, M=C8, K=01, P=3A, Q=03, T=96)
Properties settings using 
external Light Sensor: 
 
 
 
 
 
 
Sec 4.2
(IIT IO Board settings: X=05, Y=0A, M=C8, A=10)