Connecting the back panel (continued), Setup connecting alarm input/output terminal – JVC TK-C1531EG User Manual
Page 24

24
Connecting alarm input/output terminal
Ⅵ Alarm input terminal
Connect infrared sensor, door sensor, metal sensor or sensor of manual
switch and the like.
● To prevent noise from entering the internal circuit, supply non-voltage
setting signal.
● Do not supply voltage.
● Can be set via menu whether to set to alarm when the contact is short
(MAKE), or when the contact is open (BREAK). (
● Supply such that the alarm signal continues for more than 200 ms. The
recognition of alarm signal may not be guaranteed if less than 200 ms.
Ⅵ Alarm output terminal
Connect to alarm devices such as alarm, indicator, light or buzzer.
● Open-collector Low signal.
● Maximum voltage 25 V, current 30 mA.
Connecting the back panel (continued)
Z
CLASS 2 ONLY(U TYPE)
ISOLATED POWER ONLY(E TYPE)
SEE INSTRUCTION
MANUAL
POWER
VIDEO OUT
SELECTOR
SET
MENU
INT
LL
ON
RX TERM-OFF
+
1
2
DC12V d
AC24V H
IN
GND
Z Please use a shilded cable.
AUX
GND
22ǡ
TK-C1530_EN.book Page 24 Friday, August 24, 2007 9:29 AM