Comfort PLUS Whirlpool Bath

Installation and Operation

www.jacuzzi.com

Page 9

English

Subfloor

Prepare the subfloor for the drain and ensure that the area is level.

1

The drain/overflow of the bathtub extends below the bottom of the bathtub. Identify the drawing in the Technical

Specifications Manual that corresponds with your bathtub.

2

Make appropriate cuts to the subfloor to accommodate the drain.

3

Jacuzzi’s Tru-Level™ base is a standard feature on all bathtubs. If the subfloor is level and a continuous surface,

no other preparation is necessary. Proceed to the “Installation” section.

4

If the subfloor is not level, you must level the entire surface prior to installing the bathtub. The materials used

will insure that the bathtub is supported from the bottom. These materials include: leveling compound, mortar,

plaster or minimal expansion structural foam (having a density of a minimum 5lbs/cubic foot). The bathtub must

remain level in order for it to drain properly and must make contact with the leveling material. Both sides of a joint

or splice of subfloor should be level to each other.

Risk of electric shock. Connect only to a circuit protected by a GFCI.

When using electrical products, basic precautions should always be followed:

Always follow local building and electrical codes.

Grounding is required. The unit should be installed and grounded by a qualified electrician.

Two separate GFCI protected circuits are required.
A separate, 120VAC, 15 AMP GFCI circuit is required for the pump/motor.
A separate 120VAC, 15AMP, GFCI protected circuit is required for the heater.

Risk of component overheat. Do not use electric extension cord to power this unit.

Operating the motor/pump without enough water in the bathtub can cause permanent damage to the pump.

Electrical Connections

Pump/Motor with Heater

Electrical outlets must be mounted 4˝ (101mm)

above the floor line, or in accordance with local

building and electrical codes.

If the GFCI units indicate a malfunction, per manufacturer’s instructions, turn OFF power and do not use the

bathtub until the source of the problem has been identified and corrected.

(101mm)

-

The pump/motor and heater require a dedicated

120VAC, 15 Amp GFCI protected circuit for each.

The electrical outlets are not provided.

-

Power cord from the pump/motor is routed to a

control box t the factory. A supplied power cord

from the control box with a 120VAC, 15 AMP plug

connects to the customer-supplied GFCI protected

circuit.

-

Bonding lugs are provided on the motor to satisfy

local electrical codes.

-

At initial start-up, test GFCI units for proper

operation. Follow the manufacturer’s direction for

testing and proper use.

Figure 2