Venue Performance Series User’s Guide

AC POWER REQUIREMENTS

JBL DrivePack

®

DPC-2 systems are equipped with a DP multi-channel Crown Dual-Bridged Technology

power amplifier and loudspeaker specific DSP electronics and require appropriate AC power.

CAUTION: In compliance with safety agency criteria and proper system operation, it is critical
that the system installer observe all electrical safety practices at all times and provide proper earth
grounding for all AC Power connections.

AC POWER CORD KIT

120VAC North America NEMA 5-15 Edison type AC plug to PowerCon

®

connector and 240V Europe CEE

7/7 Schuko type AC plug to PowerCon connector cord sets are provided with this JBL DrivePack product
for light-duty shop testing or system configuration type use.

One spare gray Neutrik (P/N NAC3FCB) PowerCon connector is included in the AC Power Cord Set for
your convenience to create a pass-through AC power cable. To create a light-duty pass-through cable
the system installer may choose to simply cut off the AC plug from one of the provided AC cord sets and
replace it with the provided Gray PowerCon AC Outlet connector. Follow the wiring convention indicated in
Table 1.
NOTE: Tighten set screws to 2.5Nm (1.8lb-ft) torque to prevent opening by hand.

USER-FABRICATED AC POWER DISTRIBUTION

System owners may choose to fabricate or purchase a custom AC Power cable infrastructure optimized for
their specific JBL DrivePack system configuration. See Table 1 for custom application wiring and connector
information.
NOTE: Parts not provided.

CAUTION: Do not exceed 80% current rating of any AC connector at any time! See AC Power
Rating Table for current draw information.

Table 1. User-Fabricated AC Cable and Connector Information

AC Inlet Cable Connector

Neutrik PowerCon

®

NAC3FCA quick lock 3-pole A-type

cable connector for power inlet. Rated current per contact:
20 A (rms), Rated Voltage: 250VAC.

AC Outlet Cable Connector

Neutrik PowerCon

®

NAC3FCB quick lock 3-pole B-type

cable connector for power outlet. Rated current per contact:
20 A (rms), Rated Voltage: 250VAC.

Wiring

Cable: screw-type terminals or soldering nom. wire size/con-
tact: 2.5 mm² / 14 AWG

Wiring convention

Ground – Ground, Neutral – Neutral, AC Hot – AC Hot

With the two non-interchangeable types of connectors (A-type, B-type) it is impossible to produce a short
circuit. Mating connectors (combination) are identified by mechanical keyways and by color.

Table 2. Power Connector Coding

A-type (POWER INLET);

Cable connector: Blue

B-type (POWER OUTLET)

Cable connector: Gray, with
Blue bushing