A2.0 Checking Voltages To Devices
Device voltages are often measured at the circuit board to determine whether the board or the device
is bad. If the circuit board delivers voltage when the device operation is called, the circuit board is prob-
ably good and the problem lies with the device or the wiring to the device. The following voltage chart
shows operating voltages for all major hot tub components. Voltage is considered good if it is within
±10% of the listed value. Refer to appendix pages 50-51 for your specifi c circuit boards test point loca-
tions.
• 2004 ProTech LED J-315, J-325 Models (US/Canada 60Hz)
Device
Test Points
Voltage ±10%
Pump (Low Speed)
18 and 19
120 VAC
Pump (High Speed)
18 and 20
120 VAC
Circulation Pump
16 and 17
120 VAC
Heater
6 and 7
120 VAC or 240 VAC*
Ozone Generator
14 and 15
120 VAC
* Depends whether hot tub is connected to 120 VAC or 240
VAC supply
• 2004 ProTech LED J-335, J-345 (US/Canada/Export 50/60Hz)
Device
Test points
Voltage ±10%
Pump 1 (Low Speed)
18 and 19
240 VAC
Pump 1 (High Speed)
18 and 20
240 VAC
Pump 2 (J-340 Only)
21 and 22
240 VAC
Circulation Pump
16 and 17
240 VAC
Heater
6 and 7
240 VAC
Ozone Generator
14 and 15
240 VAC
A3.0 Checking Current Consumption Of Devices
This table lists the current draw for most major hot tub components.
J-315, J-325 Model (US/ Canada 60Hz)
Device
Current Consumption ±10%
Pump High/Low
10.6 - 13.6A / 2.6 - 3.9A
Heater
16.6A (240 VAC) / 8.3A (120 VAC) 14.5 Ohms
Circulation Pump
0.5A
Ozone Generator
0.1A
J-335, J-345 Models (US/Canada 60Hz)
Device
Current Consumption ±10%
Pump 1 High/Low
7.0A - 9.5A / 2.5A - 3.2A
Pump 2 High
6.8A - 9.3A
Heater
22A - 25A
10.5 Ohms
Circulation Pump
0.5A
Ozone Generator
0.1A