beautypg.com

0 troubleshooting without the control panel, 1 no heat or not enough heat, 27 8.0 troubleshooting without the control panel – Jacuzzi j315 User Manual

Page 27

background image

27

8.0 Troubleshooting Without The Control Panel

• Diagnostic Tools for Sections 8.1A - 8.1D: Clamp-on ammeter, voltmeter and ohmmeter.
• Suggested Spare Parts for Sections 8.1A - 8.1D: Circuit board, control panel, temperature sensor,
fl ow switch, heater assembly, hi-limit, circulation pump. Refer to page 59 for additional information.

8.1A No Heat Or Not Enough Heat
• Symptoms:
Circulation pump (heating pump) is moving water, panel heat indicator is lit. water is not
getting hot.
• Confi guration:
Protech LED system heaters will not operate with both jet pumps (J-345 only) running
in high speed if the circuit board is confi gured for 30 or 50 Amp operation. See section 6.1, page 23.

Standard Troubleshooting Approach

Replace or reconnect wires

between heater output and

heater element.

Circuit Board Illustrations

A. 2002+ Protech LED Models (Page 50-51)

Replace heater.

Replace Thermal Switch

Is voltage present at heater

input? Test points 4 and 5.

Replace or reconnect wires

between heater input relay

and TB1 (main power

terminal block).

Replace circuit board.

Place thermometer against heater

housing and verify temperature.

Is temperature above 130 F?

Locate thermal switch inside

heater box. Set voltage meter to

500-1000 VAC range. Test

thermal switch by connecting

voltage meter across the

terminals with a heat call present

(see fig. C). If 120 VAC* or 240

VAC exists, the switch is open. If

no voltage exists, the switch is

closed. Is the switch open?

*Convertible J315 and J325

models only.

Is voltage present at heater

element? Test points 8 and 9.

No

No

No

No

Yes

**Call Technical Support

Yes

Yes

Yes

Yes

Current draw is proof that

heater element is working.

Make sure customer knows

how to use control panel and

heater. Ask about any possible

error messages.

Yes

No

No

Is there current draw? Refer

to section A3 (page 47) for

expected heater current

consumption values.

Check heater element with

clamp-on ammeter around one

of the heater element wires.

Is the heater element’s current

draw within –10% of its listed

value?

Turn up temperature setpoint

to initiate a heat call (must be

in "standard mode" F0-F3; see

page 21). Is voltage present

at the heater output? Test

points 6 and 7.

fig. C

Thermal Switch

Bad

Thermal Switch

Good

VAC

VAC

Optional Test Method: you can also

remove one wire from either side of switch

and test across its terminals for continuity.

Infinite =bad switch; 0 =good switch

Danger: Electrical Shock Hazard Exists!
High Voltage Present On Circuit Board. Use Ex-
treme Caution While Servicing Circuit Board.

**Warning: heater temperature may have ex-
ceeded 130ºF (54ºC). Inspect heater. Call tech-
nical support if visible damage is apparent.

This manual is related to the following products: