9 pump runs and quits during jet mode – Jacuzzi j315 User Manual

Page 41

background image

41

8.9 Pump Runs And Quits During Jet Mode
This is usually a problem of the pump overheating. The pump motor incorporates a ther-
mal cutout that triggers when the motor gets too hot. There is no reset for this condition.
When the motor cools, the thermal switch resets automatically. In some cases, a faulty
circuit can also cause this problem.

Diagnostic Tools: Clamp-on ammeter, voltmeter.

Suggested Spare Parts (Page 59): Circuit board, pump.

Standard Troubleshooting Approach

Danger: Electrical Shock Hazard Exists!
High Voltage Present On Circuit Board. Use Ex-
treme Caution While Servicing Circuit Board.

Press JETS 1
button. Does pump
make a "laboring"
sound?

Pump has thermally
shut down. See
page 43.

Call an electrician to
fix problem.

Replace pump.

Is there sufficient
voltage connected to
hot tub. Check for
240 VAC –10% (or
120 VAC –10% for
J315, J325 Models)
at TB1 test points 1
and 2.

Check voltage with
pump running. Is
the voltage 240 VAC
–10 % (or 120 VAC
–10% for J315, J325
models) at test
points 1 and 2.

Is voltage from circuit board
to pump correct after pump
quits? Check for 240 VAC
(120 VAC for J315, J325
models) at recommended
test points. See table at right
for a listing of recommended
test points.

Replace circuit
board.

No

No

Yes

Yes

Yes

Yes

No

This is caused by
insufficient wiring or
the pump drawing
too much current.
Contact Jacuzzi
Premium Technical
Support.

No

Circuit Board Illustrations

A. 2002+ Protech LED Models (Page 50-

51)

Recommended Test Points

1. Low Speed Pump 1 - test points 18 & 19

2. High Speed Pump 1 - test points 18 & 20

3. Pump 2 - test points 21 & 22