Error messages: beep codes, Error messages: beep codes -10 – Intel Express 5800 TM700 User Manual
Page 110

TM700 User Guide - Problem Solving
5 - 10
Error Messages: Beep Codes
If an error occurs during the POST, the server beeps, indicating the type of error. Each
number indicates the number of short beeps.
Table 5 - 2: POST Error Beep Codes
Beeps Error
Recommended Action
2
Parity error
Check if the DIMM cards are mounted correctly. If the error
still occurs when the check result is normal, contact your
service representative.
3
Main memory read/write test error
4
Motherboard timer not operational
Contact your service representative.
6
Keyboard controller BAT test error
Check if the keyboard is connected correctly.
Check that there is no stuck key.
Contact your service representative.
7
General exception error
Contact your service representative.
8
Display memory error
Contact your service representative.
10
CMOS Shutdown register read/
write error