Bearing Maintenance

Page

Bearing Maintenance:

The bearing in the breaker should also be checked at least

two (2) times per year.

Switch the machine

OFF and check the bearing.

1. Remove the chute cover.

2. Unscrew the ice sweep

18

3. Removing the water shed and

unscrewing the breaker cover.

Note: Left Hand Threads

5. Inspect the bearing. There should

be plenty of grease in sight. If

grease is needed the bearing and

breaker should be removed to check

the action of the bearing.

It should rotate freely.

6. To remove the breaker, remove the

lower ice chute then take out all

four (4) Allen head cap screws and

pull the breaker off the auger and

evaporator.

7. If the bearing only needs grease,

inject grease into the bearing using

a grease needle.

4

.

Unscrewing the auger stud

See Removal and Replacement Section

to replace bearings and seals.