sysReadConfigWord
This function allows the caller to read individual shorts (16 bits) from the configuration space of a
specific device. The Register Number parameter must be a multiple of two (i.e., bit 0 must be set to “0”).
Calling convention:
int sysReadConfigWord (
int
bus_number,
int
device_number,
int
function_number,
int
register_number,
/* 0,2,4,...,254 */
UINT16
*data
);
Return values:
This function returns SUCCESSFUL when the indicated word was read correctly, or ERROR when
there is a problem with the parameters.
5.4.2.7
sysReadConfigDword
This function allows the caller to read individual longs (32 bits) from the configuration space of a
specific device. The Register Number parameter must be a multiple of four (i.e., bits 0 and 1 must
be set to “0”).
Calling convention:
int sysReadConfigDword (
int
bus_number,
int
device_number,
int
function_number,
int
register_number,
/* 0,4,8,...,252 */
UINT32 *data
);
Return values:
This function returns SUCCESSFUL when the indicated long was read correctly, or ERROR when
there is a problem with the parameters.