© 2004-2006, IMI Cornelius Inc.
Problem
Possible Cause
Solution
The machine over-freezes making
the auger movement slow or
stopped
•
The product Brix/ratio is too low
•
The screw setting for the product
consistency control system is set
too far toward the “+” position
•
The limit switch arm is bent away
from the gearmotor and prevents
contact
•
The level of the product in the bowl
is too low, exposing the auger
•
The compressor PC board contacts
don’t open
•
Check the product Brix/ratio and
correct
•
Reset the screw toward the “-”
position to produce a thinner con-
sistency product
•
Using pliers, straighten the limit
switch
arm
•
Add more product or turn the refrig-
eration “Off”
•
Replace the PC board
The machine is noisy
• The fan motor blades are hitting
internal components
• Check and correct
The main power switch is “On”.
The unit is not running.
•
The fuse(s) are blown
•
The pressure cutout switch has
activated
•
Some electrical connections are
not complete
•
The main power is not functioning
•
Replace the fuse(s)
•
Clean the condenser or add venti-
lation space around the machine
(the cutout switch reset is auto-
matic when the conditions are cor-
rected)
•
Check the contacts and correct
those that are incomplete
•
Replace the switch
Product is leaking out of the bowl
• One of the bowl seals is not in
place
• Replace or reposition the seals
Product is leaking from the dis-
pensing valve
•
The dispensing valve has been
incompletely or incorrectly replaced
in its position
•
The free movement of the dispens-
ing valve is impeded
•
Dispensing valve o-rings are dam-
aged
•
Reassemble and replace
•
Clean and lubricate the valve and
valve cylinder with the lubricant
provided with the machine
•
Replace the o-rings
Product is flowing into drain tray
through drainage tube
•
The bell shaped “shaft” seal
between the front of the cylinder
and the auger hub has not been
reinstalled properly
•
The bell shaped “shaft” seal or the
spindle bushing seal is damaged or
worn
•
Find the seal and put it back in
place
•
Replace the damaged/worn seal
and check the condition of the
driveshaft.
The auger is not turning
•
Auger not turned on
•
Some electrical connections are
not complete
•
The gear motor(s) are malfunction-
ing
•
Turn auger on
•
Check the contacts and correct the
ones that are incomplete
•
Replace the gear motor(s)
The auger is creating noises as it
rotates
•
The large red bowl seal is not in
position, causing the gear teeth not
to mesh
•
The product brix is incorrect
•
The bell shaped “shaft” seal has
been replaced without lubrication
or is damaged
•
The auger has been incompletely
or incorrectly reassembled (ie the
auger’s gear pins are not properly
seated)
•
Check and correct
•
Check the product brix and correct
•
Replace or Clean and lubricate
with the lubricant provided with the
machine
•