beautypg.com

Group ii invacare, Therapeutic support surfaces invacare, Therapeutic support surfaces – Invacare CG10180CA User Manual

Page 7: Invacare, Microair, 3500s, Low air loss system, Lateral turning mattress

background image

Group II

Invacare

®

Therapeutic Support Surfaces

Invacare

®

Therapeutic Support Surfaces

7

Invacare

®

microAIR

®

3500S

Low Air Loss System

Model no. BB9572000

Invacare

®

Low Air Loss with Alternating Pressure Mattress Replacement System

Model no. MNS500AP, MNS500AP-B

Invacare

®

Lateral Turning Mattress

Model no. MNS600-S, MNS600-B

Features_____________________________________

“True” low air loss therapy provides 135 liters per minute
of air circulating between the patient and the surface

16 individual 8" air cells for deep patient immersion

5, 10, or 15 minute adjustable cycle time for alternating
pressure

Ten comfort settings, plus Fowler key

Auto-firm with automatic readjust after 30 minutes

Power failure and low pressure alarm with alarm silence
option

Built-in 2" mat for patient transport or power outages

Waterproof, vapor permeable pad reduces friction

Single connector rapid attach and CPR deflate at the
power unit

Features_____________________________________

16 individual 8" air cells for deep patient immersion

Adjustable modes for rotation therapy of 15˚, 25˚, 30˚, and 45˚

Variable rotation times of 10, 20, 30 and 60 minutes

Offers static, left turn, right turn or combination modes

Ten comfort settings

Auto-firm with automatic readjust after 30 minutes

Power failure and low pressure alarm with alarm silence
option

Mattress will stay inflated for up to 48 hours in the event
of power failure

Built-in 2" mat for patient transport or power outages

Waterproof, antimicrobial Ventex Recovery 5

therapy

cover reduces friction and shear

3

Avg. pressure per point for 10 subjects

CAPILLARY CLOSURE - 32 mmHg

14

18

24

(6.5)

(7.0)

(11.9)

Scapula

Sacral
Prominence

Trochanter

Features_____________________________________

“True” low air loss therapy provides 100 liters per minute
of air circulating between the patient and the surface

Three zones of 9" cells for deep patient immersion

Auto-firm with automatic readjust after 30 minutes

Ten pressure settings for patient
comfort

Waterproof, vapor permeable cover
provides a low friction surface

Recommended for use with a
transport mat (available
separately)

Whisper quiet control unit

06-059 9/26/06 7:59 AM Page 7

This manual is related to the following products: