Ole_link2, Ole_link9, Ole_link14 – ICP DAS USA TDRS4050601 User Manual
Page 75: Ole_link15
Industrial Redundant Ring Switch
– RS Series User Manual
TDRS4050601
nn
Table
– 10 Corresponding bits and system status (for svalue)
bit Corresponding to:
Condition Description
0
Power 1
a
If there is a power fail
occurring on Power 1, bit 0
will be set as 1.
1
Power 2
b
If there is a power fail
occurring on Power 2, bit 1
will be set as 1.
2
Master Ring Switch
indicator
c
If his Switch is the master
Ring Switch(the Master
LED indicator will be
“on”)
bit 2 will be set as 1.
3
Relay output status d
If the relay output is
activated, bit 3 will be set
as 1.
Table
– 11 Displayed hexadecimal number and current system status conditions
Returned
svalue in
hexadecimal
format
Corresponding 8 bits
binary numbers
Showing current
system status
condition(s):
0
00000000
a
1
00000001
b
2
00000010
c
3
00000011
a or b
4
00000100
c
5
00000101
a or c
6
00000110
b or c
7
00000111
a or b or c
8
00001000
d
9
00001001
a or d
0A
00001010
b or d
0B
00001011
a or b or d
0C
00001100
c or d
0D
00001101
a or c or d
0E
00001110
b or c or d
0F
00001111
a or b or c or d
Table
– 12 Corresponding bits and jumpers
Bit 3
Bit 2
Bit 1
Bit 0
Jumper 3
Jumper 4
Jumper 5
Jumper 6
1
on
1
on
1
on
1
on
0
off
0
off
0
off
0
off