beautypg.com

Chapter 3. problem determination, Preliminary checklist, Chapter – IBM 32x User Manual

Page 27: Problem, Determination, Preliminary, Checklist

background image

Chapter

3.

Problem

determination

Note:

Refer

to

IBM

Safety

Information

-

Read

This

First,

GA27-4004,

before

beginning

the

procedures

in

this

chapter.

Both

software

errors

or

hardware

failures

can

cause

problems

with

the

4810/4910

SurePOS

300.

This

chapter

contains

troubleshooting

information

to

help

you

determine

the

cause

of

a

problem

and

how

to

solve

it.

Preliminary

checklist

Begin

each

service

call

by

checking

all

of

the

items

in

this

preliminary

checklist.

If,

after

performing

all

the

steps,

a

problem

still

exists,

refer

to

Table

3-1

to

continue

problem

determination.

1.

Observe

the

power

light.

If

it

is

not

on,

refer

to

Table

3-1.

2.

Verify

that

the

cables

are

securely

and

correctly

connected.

3.

Verify

that

the

I/O

devices,

which

have

their

own

power

switches,

are

connected

to

an

ac

power

outlet

that

is

operating

correctly

and

that

the

devices

are

powered

on.

4.

Verify

that

the

contrast

and

brightness

controls

on

the

video

display

(if

attached)

are

set

correctly.

5.

Verify

that

all

installed

hardware

devices

(such

as

a

memory

module,

feature

card,

printer,

or

mouse)

are

connected

correctly

and

securely.

Table

3-1.

4810/4910

symptoms

Symptom

Actions

The

power

LED

is

off.

1.

Verify

that

the

power

cord

is

plugged

into

both

the

wall

outlet

and

the

back

of

the

terminal.

2.

Verify

that

the

voltage

switch

setting

is

correct

for

your

area.

3.

Verify

that

the

terminal

is

powered

on.

4.

Verify

that

there

is

power

from

the

outlet.

5.

Disconnect

all

attached

devices

and

feature

cards

to

determine

if

one

is

overloading

the

power

supply.

If

the

power

light

returns,

reconnect

them

one

at

a

time

to

determine

the

failing

field-replaceable

unit

(FRU).

6.

Ensure

that

all

internal

cabling

and

memory

modules

are

correctly

inserted.

7.

Exchange

the

power

supply.

8.

Exchange

the

system

board.

Terminal

is

not

operating.

1.

Unplug

the

power

outlet,

wait

5

seconds,

and

then

power

ON.

Verify

that

the

power

light

on

the

front

panel

is

on.

Look

for

any

error

messages

and

listen

for

a

beep

at

the

completion

of

the

POST.

2.

Check

for

a

blown

fuse,

a

tripped

circuit

breaker,

or

a

power

failure.

3.

Verify

that

all

cables

are

securely

connected

to

and

inside

of

the

terminal.

Power

on,

LED

does

not

light.

Replace

the

LED

assembly.

11-9-2005

©

Copyright

IBM

Corp.

2002,

2004

3-1

|
|
|