Ives Heavy Duty Top Center Pivot 7259 User Manual
Installation instructions, 7259 heavy duty top center pivot
7259
Heavy Duty Top Center Pivot
Improper pivot set installation can lead to personal injury or property damage. Follow
all instructions carefully. For questions contact Technical Support at 1-888-371-7331.
CAUTION
!
1. Prepare and mortise top of door and head jamb to receive pivot set. Determine pivot location
using dimensions on reverse side. Standard templating for this center pivot has the pivot
point located 2-3/4” from side jamb. The pivot point of top pivot set must be plumb with
bottom pivot point. The finish plate should be removed from frame leaf prior to installation.
2. Locate, drill, and tap 1/4-20 mounting holes for metal door or metal frame. Locate and drill
pilot holes for #14 wood screws for wood door or wood frame. Install pivot leafs with 1/4-20 x 3/4”
FHMS or #14 FHWS screws provided. Attach finish plate to frame leaf.
3. The pin of top pivot set should be retracted now for ease of installation. Insert 5/32” Allen wrench
through access hole and into pin adjustment screw. Rotate Allen wrench counterclockwise
until pivot pin is completely retracted (Figure 1).
4. Install bottom pivot set. Once bottom pivot set is installed and secured, hang the door.
5. With door in open position (about 90° to jamb), carefully fit door onto bottom pivot. Refer to
bottom pivot instruction sheet. With door in vertical position, align top pivot leafs in door
and jamb. With pivot leafs aligned, insert 5/32” Allen wrench through access hole into pin
adjustment screw. Rotate Allen wrench clockwise until pin adjust screw seats and pivot pin
is in normal position (Figure 1). The door should now swing freely. If it does not, double
check templating dimensions.
Frame leaf
Finish plate
Door leaf
Pivot
pin
Figure 1
To retract
pivot pin
Access
hole
Pin adjust screw
With pin
retracted
Normal pin
position
Installation Instructions
26676 Rev. 4
© 2006 Ingersoll-Rand Company Limited