Reset mode, Rst no, Rst yes – Miller Electric Auto-Axcess 450 User Manual
Page 34: Cycl pwr, 7. reset mode
OM-210 540 Page 30
4-7.
Reset Mode
198 993 / 803 246-B
.
Reset mode is not active when
Program Lock is enabled.
The reset mode allows the operator to
reload factory program settings for all
eight active programs in the unit.
.
System configuration data will be
lost during the Reset operation.
Enter reset mode by turning power On and pressing
the Program Push Button until the RST NO message
is displayed. RST NO message will not display until
after the power-up sequence is completed
(approximately 20 seconds).
RST
NO
Rotate Adjust knob to change NO
to YES.
Program 1
Pulse
.035 Mild Steel
90% Argon, 10% CO
2
Program 2
MIG
.035 Mild Steel
75% Argon, 25% CO
2
Program 3
Accu-pulse
.035 Mild Steel
90% Argon, 10% O2
Program 4
Pulse
.045 Mild Steel
90% Argon, 10% CO
2
Program 5
MIG
.045 Mild Steel
75% Argon, 25% CO
2
Program 6
Accu-pulse
.045 Mild Steel
90% Argon, 10% O2
Program 7
Pulse
.052 Mild Steel
90% Argon, 10% CO
2
Program 8
MIG
.052 Mild Steel
75% Argon, 25% CO
2
RST
YES
RST
YES
CYCL
PWR
Press the Arc Control button to
confirm the reset.
The reset message is displayed for
2 seconds while factory program
settings are being reloaded.
During the reset mode the following
factory default programs are loaded
into the unit:
Cycl Pwr message appears on the display
when programs complete loading.
Turn power off, wait 10 seconds, and turn
power back on again to complete the reset
operation.
.
After Reset is complete, be sure to load
appropriate programs that contain the
correct wire size, process, and shielding gas
for the welding operation