The following steps describe how to properly install the cables between a secondary Metrologic scanner and the
MS2421/MS2422 scanner. The MS2421/MS2422 and the secondary scanner must then be configured to communicate
properly. Cable installation alone does not guarantee that the MS2421/MS2422 scanner will communicate properly with the
host system and secondary scanner.

Contact a Metrologic customer service representative before connecting another manufacturer’s scanner to the
MS2421/MS2422 as a secondary scanner.

Configuration bar codes are located in the
MS2

xxx Stratos Series Configuration Addendum (

MLPN

00-02034

x) under Scanner Configuration Bar Codes:

Auxiliary Port, Quick Start for a Secondary Metrologic Scanners.



1. Refer to pages 16 - 20 for the type of interface (RS232, IBM 46xx, etc.) required for your application. Follow the cable

installation steps under the appropriate interface before continuing. Once the communication and power cables have
been installed follow step 2 below for the secondary scanner installation.


2. Connect

the

straight end of the RS232 PowerLink AUX cable (

MLPN

57-57099

x-3) into the RS232 socket of the secondary

scanner (see figure on page 23).


3. Connect

the

angled end of the RS232 AUX cable (

MLPN

57-57099

x-3) into the 10-pin socket labeled Aux RS232 In, on

the bottom of the MS2421/MS2422 scanner.

Important: The MS2421/MS2422 series’ aux port requires the signals; transmit, receive, RTS & CTS from the secondary

scanner.

MS2421/MS2422 scanner auxiliary port will support 5VDC devices with a 150mA maximum current. If the auxiliary
device exceeds this specification an external power supply will be required to power the auxiliary device.

The following Metrologic scanners can receive power from the MS2421/MS2422 scanner: the MS9520, MS9540,
and the MS5145.


4. This step is required for secondary devices that require >5VDC and/or 150mA current to operate. Skip to step 5 if

the secondary device requires ≤ 5VDC.

Plug the power supply into the secondary scanner’s PowerLink cable (

MLPN

57-57099

x-3) and connect AC power to the

secondary scanner.

Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet
should be located near the equipment and be easily accessible.


5. Configure

the

MS2421/MS2422

scanner and the secondary scanner. The auxiliary input port’s data format must match

the main output format of the secondary scanner.

Refer to the MS2

xxx Stratos Series Configuration Addendum (

MLPN

00-02034

x) under Scanner Configuration

Bar Codes: Auxiliary Port, Quick Start for a Secondary Metrologic Scanners.