Mq ga-2.9r — preparation for long -term storage – Multiquip Portabe AC Generator (Gasoline Engine) GA-2.9R User Manual
Page 25

MQ GA-2.9R A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #0 (10/28/04) — PAGE 25
MQ GA-2.9R — PREPARATION FOR LONG -TERM STORAGE
Generator Storage
For storage of the generating set for over 30 days, the
following is required:
■ Drain the fuel tank completely, or add STA-BIL to the fuel.
■ Run the engine until the gasoline in the carburetor is
completely consumed.
■ Completely drain the oil from the crankcase and refill with
fresh oil.
■ Remove the spark plug, pour 2 or 3 cc of SAE 30 oil into the
cylinder and crank slowly to distribute the oil.
■ Slowly rotate the engine a few times with the starter Rope and
install a new plug.
■ Pull out the starter rope slowly and stop at the compression
point.
■ Clean all external parts of the generating set with a cloth.
■ Cover the generating set and store in a clean, dry place.