PAGE 24 — MQ GA-2.9R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #0 (10/28/04)

6. If the engine has started, slowly return the choke lever

(Figure 12 ) to the

“OPEN”

position. If the engine has not

started repeat steps 1 through 5.

7. Before the generator is placed into operation, run the engine

for 3-5 minutes. Check for abnormal smells, fuel leaks, and
noises that would associate with lose components.

8. Refer to the AC voltmeter (Figure 15) on the control

box. The voltage indicated on the voltmeter should be
120 VAC with no load applied.

Figure 15. AC Voltmeter (120 VAC)

11. If desired, verify with a voltmeter (Figure16) that 120

VAC is present at the GFCI duplex receptacle and the
120V twist-lock receptacle.

MQ GA-2.9R— INITIAL START-UP ENGINE/OPERATION

Connecting the Load

1. Connect the load to the output receptacles.

2. Place the main circuit breaker (Figure 17) in the ON

position.

Figure 16. 120 VAC GFCI Receptacle

Stopping The Engine

Normal Shutdown

1. Place the

main circuit breaker (Figure 10) in the OFF

position.

2. Remove the load from the generator, and let the engine

run at idle for 3-5 minutes with the idle control switch in
the ON position (Up)

5. Place the

engine ON/OFF switch

(Figure 18) in the "

OFF

"

position.

6. Place the engine

fuel valve lever

(Figure 19) to the "OFF"

position.

Emergency Showdown

1.

Place the

engine ON/OFF swith (Figure 18) in the

"OFF" position.

Figure 19. Engine Fuel Valve Lever (OFF Position)

Figure 18. Engine ON/OFF Switch (OFF)

Figure 17. Main Circuit Breaker (ON)