Moxa Technologies NPort 5400 User Manual
Page 54

NPort 5400 Series User’s Manual
Web Console Configuration
5-29
Password changed
The user has changed NPort’s password. When the password changes, NPort will send an e-mail
with the password change notice before NPort reboots. If the NPort fails to send mail to the mail
server after 15 seconds, NPort will be rebooting directly and abort the mail auto warning.
DCD changed
The DCD (Data Carrier Detect) signal has changed, also indicating that the modem connection
status has changed. For example, a DCD change to high also means “Connected” between local
modem and remote modem. If the DCD signal changes to low, it also means that the connection
line is down.
When the DCD changes, NPort will immediately send an e-mail or send an SNMP trap.
DSR changed
The DSR (Data Set Ready) signal has changed, also indicating that the data communication
equipment’s power is off. For example, a DSR change to high also means that the DCE is powered
ON. If the DSR signal changes to low, it also means that the DCE is powered off.
When the DSR changes, NPort will immediately send an e-mail or send an SNMP trap.
Setting
Factory Default
Necessity
Enable, Disable
Disable
Optional
This feature helps the administrator manage the NPort. NPort sends mail to pre-defined mail boxes
when the enabled events—such as Cold start, Warm start, Authentication failure, etc.—occur. To
configure this feature, click on the event type box.
Trap
Setting
Factory Default
Necessity
Enable, Disable
Disable
Optional
This feature helps the administrator manage the NPort. NPort send SNMP Trap to a pre-defined
SNMP Trap server when the enabled events—such as Cold start, Warm start, Authentication
failure, etc.—occur. To configure this feature, you need to click on the event type box.
ATTENTION
DCD changed and DSR changed event only supported by those models, which have these two
signals. For example NPort 5210, 5410 and NPort 5610.