All electrical work must be
performed by a qualified person in
accordance with local and national
safety regulations.
The machine comes equipped for
connection to a 208 V, 60 Hz, 3 phase
power supply. It is equipped with a 6 ft.
long, 12/4 AWG power cord, without a
plug. A plug, rated for the required
power which will fit the receptacle, is to
be supplied by the electrician doing the
installation. It should be connected to
the main power supply.
Voltage:
208 V, 3 phase
Frequency:
60 Hz
Rated Load:
6 kW
Circuit breaker:
3 x 20 A
Black : connect to L1 (hot)
Red:
connect to L2 (hot)
White: connect to L3 (hot)
Green: connect to GND (ground)
It can be converted to use a single
phase power supply in accordance
with the conversion and wiring diagram.
The cord must be changed from a
12/4 AWG to a 10/3 AWG. Contact
Miele Technical Service for more
information
Voltage:
208 V, 1 phase
Frequency:
60 Hz
Rated Load:
6 kW
Circuit breaker:
2 x 30 A
^ Connection should be made via a
suitable isolator, with an "On/Off"
button easily accessible for servicing
work.
^ A damaged power cord must only be
replaced with a genuine Miele cord
by a Miele service technician.
WARNING
THIS APPLIANCE MUST BE
GROUNDED
Electrical connection