beautypg.com

Ga-4.5r/ga-4.5ra — controls and indicators – Multiquip Portable AC Generator GA4.5R User Manual

Page 16

background image

PAGE 16 — GA-4.5R/GA-4.5RA A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #1 (11/27/06)

GA-4.5R/GA-4.5RA — CONTROLS AND INDICATORS

Figure 2C. Full Power Switch 120VAC (Up)

Simplified Wiring Diagram

Figure 2D. Full Power Switch 120/240 VAC (Down)

Simplified Wiring Diagram

11. Full Power Switch – The generators are provided with a

full power switch. Figures 2C and 2D show simplified wiring
diagrams of the dual voltage system.

When the full power switch is in the 120 volt (up) position,
you can access the

full rated power

of the generators at

120 volts from the GFCI duplex receptacle and the120V
twist-lock receptacle, or a combination of both receptacles
as long as the total load does not exceed the generating
set capacity.

When the switch is in the 240 volt (down) position, you can
acess

half of the rated power of the generating set at 120

volts from the GFCI duplex receptacle and up to half of the
rated power of the set at 120 volts from 120V twist-lock
receptacle; or full rated power of the set at 240 volts from
the 240V twist-lock receptacle.

When the

full power switch is in the

120V position, the 240V twist-lock
receptacle

cannot be used.

NOTE

Figure 2B. Generator Controls and Components (continued)

This manual is related to the following products: