beautypg.com

Service and maintenance – Maytag ELECTRIC WATER HEATER HR630DJLS User Manual

Page 16

background image

UPPER THERMOSTAT ADJUSTABLE

BEHIND UPPER ACCESS PANEL

LOWER THERMOSTAT ADJUSTABLE

BEHIND LOWER ACCESS PANEL

16

Service and Maintenance

The thermostat(s) of this water heater have been factory
set at a position which approximates 120°F (HOT) to
reduce the risk of scald injury.

The upper and/or lower thermostat(s) are factory set at
a position which approximates 120°F (HOT) and is
adjustable if a different water temperature is desired.
Read all warnings in this manual and on the water
heater before proceeding.

HOT–Is a thermostat setting of approximately

120°F, which will supply hot water at the
most economical temperatures.

A–Is a thermostat setting of approximately

130°F.

B–Is a thermostat setting of approximately

140°F.

C–Is a thermostat setting of approximately

150°F.

VERY HOT–Is a thermostat setting of approximately

160°F. It is recommended that the dial be
set lower whenever possible.

NOTE: Water temperature range of 120°–140°F
recommended by most dishwasher manufacturers.

Thermostats

Temperature Settings

Temperature Regulation

WARNING

Never allow small children to use a hot water tap, or to
draw their own bath water. Never leave a child or
handicapped person unattended in a bathtub or shower.

WARNING

HOTTER WATER CAN SCALD: Water heaters are intended
to produce hot water. Water heated to a temperature which
will satisfy clothes washing, dish washing, and other
sanitizing needs can scald and permanently injure you
upon contact. Some people are more likely to be
permanently injured by hot water than others. These include
the elderly, children, the infirm, or physically/mentally
handicapped. If anyone using hot water in your home fits
into one of these groups or if there is a local code or state
law requiring a certain temperature water at the hot water
tap, then you must take special precautions. In addition to
using the lowest possible temperature setting that satisfies
your hot water needs, a means such as a mixing valve,
should be used at the hot water taps used by these people
or at the water heater. Mixing valves are available at
plumbing supply or hardware stores. Follow manufacturers
instructions for installation of the valves. Before changing
the factory setting on the thermostat, read the “Temperature
Regulation” section in this manual.

LOWER THERMOSTAT

WITH HIGH LIMIT

LOWER THERMOSTAT

WITHOUT HIGH LIMIT

160°F

About 1/2 seconds

150°F

About 1-1/2 seconds

140°F

Less than 5 seconds

130°F

About 30 seconds

120°F

More than 5 minutes

Time to Produce

2nd & 3rd Degree

Temperature Setting

Burns on Adult Skin