Figure 29 - Pilot Flame

Thermopile

Thermocouple

Turn off gas before servicing fireplace. It is recommended that a qualified service
technician perform these check-ups at the beginning of each heating season

W

ARNING

BURNER FLAME
The flames from the burner should be visually checked

as soon as the heater is installed and periodically during

normal operation. In normal operation, at full rate, and

after operating for about 15 to 30 minutes, the flame

should be yellow and slightly taller than the rear log.

See Figure 30.
NOTE: The type of installation, vent system
configuration, and wind effects may cause the
flame patterns to vary.

Figure 30 - Burner Flame Appearance

CLEANING AND MAINTENANCE

BURNER, PILOT AND CONTROL COMPARTMENT

Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a

year. Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times.
PILOT FLAME
The flames from the pilot should be visually checked as soon as the heater

is installed and periodically during normal operation. The pilot flame must

always be present when the fireplace is in operation. See Figure 29. The pilot

flame has three distinct flames, one engulfing the thermopile, one engulfing the

thermocouple, and the other reaching to the main burner.

.

BURNER
Inspect area around the injector. Remove any lint or foreign material with a

brush or vacuum.