Electrical installation, Warning, Caution – Monessen Hearth Natural Vent Gas Fireplace SBV400 User Manual

Page 21: Remote wall mounted switch, Do not connect wall switch to ac (110v) circuit

background image

62D4036

21

ON

OFF

OPTIONAL REMOTE

WALL SWITCH

ON

OFF

OPTIONAL REMOTE

WALL SWITCH

PILOT

HI

LO

ON

OFF

TH
TP

TH/TP

ON

OFF

SPILL

SWITCH

RS

REMOTE WALL MOUNTED SWITCH

A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junc-

tion box at the desired location on the wall. See Figure 19. Do not extend beyond the wall switch wire length provided.
NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire
is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.

Figure 19 - Wiring Diagram for Wall Switch

ELECTRICAL INSTALLATION

ELECTRICAL WIRING

Electrical connections should only be performed by a qualified, licensed electrician.
Main power must be off when connecting to main electrical power supply or performing
service. All wiring shall be in compliance with all local, city, and state codes. The
appliance, when installed, must be electrically grounded in accordance with local
codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA
70 (latest edition)
and Canadian Electrical Code, CSA C22.1.

W

ARNING

Label all wires before disconnecting when servicing controls. Wiring errors can cause
improper and dangerous operation.

CAUTION

Verify proper operation after servicing.

Do not connect
wall switch
to AC (110V)
circuit.

W

ARNING