Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: Short circuit. The decoder is connected to
locomotive or the carriage ground.
à Check the connections. A short circuit can result in irreparable
damage.
§
The lamps flicker (this is not a defect).
Possible cause: The lamp is connected with one side to ground.
à If you do not want the lamp to flicker, disconnect it from ground,
insulate it and connect it to the return conductor of the
corresponding output.
§
The decoder does not react on the data sent by the central unit.
Possible cause: The connections X5 and X6 have been exchanged.
à Check the connections.
If you cannot find the problem, please return the decoder for repair
(address on the cover page).