7. ac generator power curve, 8. optional three-phase generator curves – Miller Electric Big Blue 500 PT User Manual
Page 23

OM-4429 Page 19
4-7. AC Generator Power Curve
193 018
The ac power curve shows the gen-
erator power in amperes available
at the 120 and 240 volt receptacles.
0
50
100
150
200
250
300
0
5
10
15
20
25
30
AC AMPERES IN 240V MODE
AC VOL
TS
0
25
50
75
100
150
125
0
10
20
30
40
50
60
AC AMPERES IN 120V MODE
4-8. Optional Three-Phase Generator Curves
197 472 / 197 473
The ac power curves show the gen-
erator power available in amperes
at the single-phase 120/240 volt re-
ceptacle or three-phase 240 volt
terminals.
A. 12 kVA/kW Single-Phase AC Output (No Weld Load)
B. 20 kVA/kW Three-Phase AC Output (No Weld Load)
180
190
200
210
220
230
240
250
260
270
280
0
20
40
60
80
100
AC AMPERES
AC VOL
TS
180
200
220
240
260
280
0
10
20
30
40
50
60
70
AC AMPERES
90
95
100
105
110
115
120
125
130
135
140
AC VOL
TS
This manual is related to the following products: