14. connecting remote control, 15. electrical service guide – Miller Electric 652 User Manual
Page 30

OM-228 470 Page 26
4-14. Connecting Remote Control
Ref. 800 170-E
!
Turn off power before con-
necting a remote control.
1
Remote 14 Receptacle RC8
Connect remote control to RC8, if
plug does not fit, wire cord to
terminal strip 1T.
!
Turn Off and disconnect in-
put power before opening
terminal strip cover.
2
Terminal Strip 1T
3
Remote Control Cord
4
Strain Relief (Customer
Supplied)
Secure cord in strain relief.
Reinstall and secure access panel.
Close door.
1
OR
OR
A
J
B
K
I
C L N
H
D M
G
E
F
C
REMOTE
OUTPUT
CONTROL
115 VAC
24VAC
REMOTE
REMOTE
VOLTAGE
SENSE
GND
REMOTE
POWER ON/OFF
S-162 895-B
E
D
I
J
A
B
N
P
K
M
L
REMOTE
CONTACTOR CONTACTOR
3
2
4
4-15. Electrical Service Guide
60 Hz Models
50 Hz Models
Input Voltage
230
460
575
380
400
440
520
Input Amperes At Rated Output
126
63
50.4
77
73
66
54
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay
2
150
70
60
90
90
80
60
Normal Operating 3
200
90
80
125
110
100
80
Min Input Conductor Size In AWG
4
1
6
6
4
4
4
6
Max Recommended Input Conductor Length In Feet (Me-
ters)
208
(64)
328
(100)
513
(156)
335
(102)
371
(113)
449
(137)
419
(128)
Min Grounding Conductor Size In AWG
4
6
8
8
6
6
8
8
Reference: 2005 National Electrical Code (NEC)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.