beautypg.com

Maytag MDE9601 User Manual

Page 21

background image

21

Electrical installation

The machine must only be connected to an

earthed wall socket.

Connection on delivery

The machine is supplied as single-phase,

230V, heat output 2500W (see type plate)

and has a 16A fuse. Any earth fault fuses

must be type A.

Alternative connection

It is possible to switch over from 16A (heat

output 2500) to 10A (heat output 1950W).

Switching must be carried out as follows:

1. Shut off the power.

2. Press and hold the Start/Stop button, and

switch on the power.

3. Release the Start/Stop button once the

programme indicator lights up.

4. Press the Start/Stop button 5 times

(within 10 seconds).

5. Adjust the programme selector so that

the Extra Dry light comes on (10 o’clock).

6. Press the Start/Stop button to store the

setting.

If you want to reset the machine to a 16A

connection:

1. Repeat steps 1-4.

2. In step 5, adjust the programme selector

so that the Extra Dry light goes out.

3. Press the Start/Stop button to store the

setting.

The machine now has a 16A connection.