Performance data – hoods, Heater parts from acf greenhouses – Modine Manufacturing BAE User Manual
Page 16

Model
PAE 50
PAE 75 PAE 100 PAE 125 PAE 145 PAE 175 PAE 200 PAE 225 PAE 250
PAE 300
PAE 350
PAE 400
S
S
S
S
S
S
S
S
S
S
S
S
8'
14
23
23
34
46
32
44
44
65
57
68
74
10'
12
21
20
30
42
29
39
39
58
51
60
66
12'
11
19
19
27
38
26
36
36
53
47
55
60
14'
–
17
17
25
35
25
33
33
50
43
51
56
16'
–
16
16
23
33
23
31
31
46
41
48
52
18'
–
–
–
22
31
22
29
29
44
38
45
49
20'
–
–
–
21
29
21
28
28
41
36
43
47
22'
–
–
–
–
–
–
27
26
40
35
41
45
24'
–
–
–
–
–
–
25
25
38
33
39
43
26'
–
–
–
–
–
–
–
–
36
32
38
41
28'
–
–
–
–
–
–
–
–
35
31
36
40
30'
–
–
–
–
–
–
–
–
34
30
35
38
32'
–
–
–
–
–
–
–
–
–
–
34
37
34'
–
–
–
–
–
–
–
–
–
–
–
36
16
PERFORMANCE DATA – HOODS
Performance Data — 30°, 60° and 90° Downward Deflector Hoods — Propeller Models
MOUNTING
HEIGHT
X
Y
Y
Z
Z
X
60° NOZZLE
30° NOZZLE
60°
30°
30° DOWNTURN NOZZLE
60° DOWNTURN NOZZLE
NOTE:
X = FEED FROM HEATER
TO START OF
FLOOR COVERAGE.
Y = FEET TO END OF
FLOOR COVERAGE.
Z = FEET TO END OF
THROW.
30° HOOD
60° HOOD
THROW-FLOOR COVERAGE
Model
PAE 50
PAE 75 PAE 100 PAE 125 PAE 145 PAE 175 PAE 200 PAE 225
PAE 250
PAE 300
PAE 350
PAE 400
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
8'
6 14 19
10 24 32 9 22 31
14 30 41 18 38 52 13 28 39 17 36 49 17 36 49
23 48 65
20 42 57
23 48 65
24 50 68
10'
–
9 21 30
8 19 27
12 29 39 17 37 51 11 26 36 15 35 47 15 34 47
22 47 64
19 41 56
22 47 64
23 49 67
12'
–
6 17 24
5 13 19
11 26 36 16 36 49 10 24 33 14 33 45 14 33 45
21 46 63
18 40 54
21 46 62
22 48 65
14'
–
–
–
9 23 32
14 34 47
7 19 27
13 31 42 12 30 42
20 44 61
16 38 52
20 44 61
21 47 64
16'
–
–
–
–
12 31 43
–
10 27 38 10 27 37
18 42 58
15 36 49
18 42 58
19 45 62
18'
–
–
–
–
–
–
7 20 29
7 20 29
17 40 56
13 33 45
16 40 55
18 43 59
20'
–
–
–
–
–
–
–
–
15 37 52
10 27 38
15 37 51
16 40 55
22'
–
–
–
–
–
–
–
–
12 32 45
–
12 32 45
14 36 51
24'
–
–
–
–
–
–
–
–
–
–
–
9 27 39
Mounting
Height to
Bottom of
Heater
30° Downward Hood For Propeller Units ➀
Mounting
Height to
Bottom of
Heater
90° Downward Hood For Propeller Units ➀
➀
Data Based on units fired at full rated input with an entering air temperature of 60°-80°F. Maximum mounting heights higher versus units without outlet devices.
Model
PAE 50
PAE 75 PAE 100 PAE 125 PAE 145 PAE 175 PAE 200 PAE 225 PAE 250
PAE 300
PAE 350
PAE 400
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
8'
0 13 18
0 24 33
0 22 30
0 32 43
0 41 56
0 30 40
0 38 52
0 38 51
0 51 70
0 45 61
0 51 69
0 53 73
10'
–
0 21 29
0 18 25
0 29 40
0 39 54
0 27 37
0 36 49
0 36 49
0 50 68
0 43 59
0 49 68
0 52 71
12'
–
0 15 21
0 9 13
0 26 36
0 37 51
0 23 32
0 34 46
0 33 45
0 48 66
0 41 57
0 48 65
0 50 69
14'
–
–
–
0 21 29
0 34 47
0 16 23
0 30 41
0 30 41
0 46 63
0 39 53
0 46 62
0 48 66
16'
–
–
–
0 15 22
0 30 41
–
0 25 35
0 25 34
0 43 59
0 35 49
0 43 59
0 46 63
18'
–
–
–
–
0 24 33
–
0 14 19
0 14 19
0 40 55
0 31 42
0 40 54
0 43 59
20'
–
–
–
–
–
–
–
–
0 35 49
0 23 32
0 35 48
0 39 53
22'
–
–
–
–
–
–
–
–
0 28 39
0 16 23
0 28 39
0 33 46
24'
–
–
–
–
–
–
–
–
–
–
0 21 30
0 22 31
Mounting
Height to
Bottom of
Heater
60° Downward Hood For Propeller Units ➀