beautypg.com

Maytag Epic z W10112937A User Manual

Page 13

background image

13

Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5"
(12.7 cm). Cut 1

¹⁄₂" (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape

ends of wires into a hook shape.

When connecting to the terminal block, place the hooked end of the wire under the screw of
the terminal block (hook facing right), squeeze hooked end together and tighten screw, as
shown.

1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor screw. Connect neutral

ground wire and place the hooked end (hook facing right) of the neutral wire (white or
center wire) of direct wire cable under the center screw of the terminal block. Squeeze
hooked ends together. Tighten screw.

3. Connect ground wire (green or bare) of direct wire cable to external ground conductor

screw. Tighten screw.

4. Place the hooked ends of the other direct wire cable wires under the outer terminal block

screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-

down screw.

7. You have completed your electrical connection. Now go to “Venting Requirements.”

A. External ground conductor screw - Dotted line shows

position of NEUTRAL ground wire before being moved to

center silver-colored terminal block screw.

B. Center silver-colored terminal block screw

C. Neutral ground wire

D. Neutral wire (white or center wire)

E. ¾" (1.9 cm) UL listed strain relief

1"

(2.5 cm)

5"

(12.7 cm)

A

C

B

D

E

A. External ground conductor screw

B. Ground wire (green or bare) of power supply cable

C. ¾" (1.9 cm) UL listed strain relief

D. Center silver-colored terminal block screw

E. Neutral ground wire
F. Neutral wire (white or center wire)

A

B

C

D

E

F