beautypg.com

How to order repair parts, Figure 8. wiring through junction box opening, Figure 9. end cap drill pattern – Marley Engineered Products D User Manual

Page 4

background image

4

another heater, it is easier for the power supply connections to be made prior

to the installation of the heater(s) to the wall. If this is not possible, connections

may be made through the opening in the junction boxes when the front cover(s)

is removed. See Figure 8.

5. Connecting power supply cables may be routed from heater to heater by drilling

a 1/2-inch (13mm) diameter hole in the end caps for the heaters that fit togeth-

er. See Figure 9. To prevent possible damage to internal heater wiring, all

drilling of end caps must be done with end caps removed from heater.

6. Wire heaters as shown in Wiring Diagram, Figure 10.

7. Replace the front covers and end caps according to “Installation of Single Unit”,

Steps 12 and 13.

OPERATING AND MAINTENANCE INSTRUCTIONS

1. An integral or remote wall thermostat is recommended for each room. In very

large rooms it is recommended that a low voltage thermostat with double or

multiple circuit relays be used to provide the most comfortable results.

DO LOCATE

DO NOT

THERMOSTAT

LOCATE THERMOSTAT

• A minimum of two feet

• Near televisions or

(61cm) from any

appliances that emit heat.

outside wall.

• Near drafts from an

• Approximately five feet

open doorway.

(1,5m) from the floor,

• Where it would be struck

preferably on an inside

by direct rays of sunlight.

wall location.

2. After the baseboard system has been completely installed, all thermostats

should be turned to LOW or NO HEAT setting. Then turn on breakers or install

fuses. Wait 3 to 5 minutes and check to see that none of the heaters are oper-

ating. If operating, disconnect power and check wiring. If none are operating

then turn the thermostats to highest setting and wait 3 to 5 minutes. Check to

see that all heaters are operating. Should any not be operating, disconnect

power and check wiring.

3. Allow entire system to operate steadily for 1/2-hour. For a period of time after

the heaters are put into operation, the owner may notice a “new smell” coming

from the heaters. This is expected on new installations. Bringing heaters to full

operation will eliminate this condition in a short period of time.

4. Select the setting for comfort on all thermostats.

5. To clean heater: Because of the convection heating principle which depends

upon circulation of air through the finned element, dust particles will periodical-

ly be deposited between the fins and should be removed occasionally for max-

imum efficiency of the heater. A vacuum cleaner with proper attachments can

easily be worked along the top and bottom of the finned element to clear it of

dust deposits.

NOTE: The painted finish of the heater may be cleaned with a slightly damp

cloth if desired. Do not use wax cleaners or polishes as these waxes may

vaporize when the heater is in operation and cause discoloration.

UNE FOIS LES CONNEXIONS
EFFECTUÉES, REPOUSSEZ LES
CÂBLES DANS LA BOÎTE DE
JONCTION.

Figure 8. Wiring Through Junction Box Opening

FRONT OF
HEATER

1

15

/

32

"

(37mm)

1

/

2

" DIA.

(13mm)

3"

(76mm)

Figure 9. End Cap Drill Pattern

LIMIT

ELEMENT

LIMIT

ELEMENT

TWO HEATERS ON ONE SUPPLY

POWER SUPPLY

Figure 10. Dual Heater Wiring Connections

WIRING DIAGRAM

HOW TO ORDER REPAIR PARTS

In order to obtain any needed repair or replacement

parts, warranty service or technical information, please
contact Marley Engineered Products Service Center toll-
free by calling 1-800-642-HEAT.

When ordering repair parts, always give the informa-

tion listed as follows:

1. The Part Number
2. The Model Number
3. The Part Description
4. Date of Manufacture

LIMITED WARRANTY

All products manufactured by Marley Engineered Products are warranted against
defects in workmanship and materials for one year from date of installation, except
heating elements which are warranted against defects in workmanship and materi-
als for ten years from date of installation. This warranty does not apply to damage
from accident, misuse, or alteration; nor where the connected voltage is more than
5% above the nameplate voltage; nor to equipment improperly installed or wired or
maintained in violation of the product’s installation instructions. All claims for war-
ranty work must be accompanied by proof of the date of installation.

The customer shall be responsible for all costs incurred in the removal or reinstal-
lation of products, including labor costs, and shipping costs incurred to return prod-
ucts to Marley Engineered Products Service Center.Within the limitations of this
warranty, inoperative units should be returned to the nearest Marley authorized ser-
vice center or the Marley Engineered Products Service Center, and we will repair
or replace, at our option, at no charge to you with return freight paid by Marley. It is
agreed that such repair or replacement is the exclusive remedy available from
Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED. AND ALL IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH
EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DIS-
CLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED
PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARIS-
ING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLI-
GENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above exclusion or limitation may not apply to you. This warranty
gives you specific legal rights, and you may also have other rights which vary from
state to state.

For the address of your nearest authorized service center, contact Marley
Engineered Products, in Bennettsville, SC, at 1-800-642-4328. Merchandise
returned to the factory must be accompanied by a return authorization and service
identification tag, both available from Marley Engineered Products. When request-
ing return authorization, include all catalog numbers shown on the products.

SWO 315

5200-2083-004

09/97

SPX Corporation
470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA