9. replacing hub assembly – Miller Electric XR A User Manual
Page 39

OM-1581 Page 35
6-9. Replacing Hub Assembly
Turn Off wire feeder and welding
power source. Remove gun top
cover and open pressure roll
assembly as shown in Section 6-4.
Retract wire onto spool and remove
spool. Take hub apart as shown.
1
Metal Brake Washer
2
Flat Washer
3
Brake Washer
4
Hub
5
Keyed Washer
6
Spring
7
Cap Screw
8
Retaining Ring
Replace broken or worn parts and
slide parts onto shaft as shown.
Adjust hub tension (see Section
6-10). Thread welding wire (see
Section 4-14). Close and latch door.
Close gun pressure roll assembly
and reinstall gun cover.
151 778-B / Ref. 143 223-A
Tools Needed:
1
2
3
4
5
6
2
7
8
7/16 in
This manual is related to the following products:
See also other documents in the category Miller Electric Tools:
- OM-2241 (32 pages)
- ICE-27C (36 pages)
- Arc Welding Power Source (4 pages)
- INVISION 456 CC (44 pages)
- Welder (132 pages)
- SS-75D12 (44 pages)
- Load Bank LBP-350 (2 pages)
- OM-193 084E (36 pages)
- 750MPa (2 pages)
- APT-1000 (20 pages)
- OM-220 390F (48 pages)
- 271 (48 pages)
- Welding (32 pages)
- DC (72 pages)
- OM-129 (70 pages)
- XLi (24 pages)
- S-64 (36 pages)
- ICE-27T (36 pages)
- PipePro 304 (76 pages)
- AA40GBU (28 pages)
- D-64 (40 pages)
- Auto Arc XLT 165 (48 pages)
- 185 DX (56 pages)
- S-32S (4 pages)
- Big 40 DC/TIG 55500 A (8 pages)
- Big Blue 600D (60 pages)
- Millermatic 140 (60 pages)
- pmn (36 pages)
- LMSW Series (2 pages)
- 1250 (46 pages)
- Trailblazer Pro 350 D (8 pages)
- TS (76 pages)
- S-22P12 (28 pages)
- 602 (40 pages)
- Axcess 300 (56 pages)
- MOG-400 (40 pages)
- WC-24 (20 pages)
- Big Blue 502P (64 pages)
- Dimension 1000 (44 pages)
- DS-74DX12 (52 pages)
- 350 VS (36 pages)
- 24A (32 pages)
- GA-16C (12 pages)
- Big Blue 502D (116 pages)
- OM-229 038D (36 pages)