Cable specifications, Technical specifications, Fiber cable – Milan Technology NDM-FTX-XX-01 User Manual
Page 3: Copper cable, Fiber cable -- continued
NDM-FTX Series Fast Ethernet Dual Media NIC
4
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours
The physical characteristics must meet or exceed the IEEE 802.3 specification.
Fiber cable
Bit error rate:
<10-9
Single mode fiber (recommended):
9 µm
Multimode fiber (recommended):
62.5/125 µm
Multimode fiber (optional):
100/140, 85/140, 50/125 µm
NDM-FTX-ST-01(x), NDM-FTX-SC-01(x), NDM-FTX-MT-01(x) 1300 nm multimode
Fiber optic transmitter power:
min: -19.0 dBm
max: -14.0 dBm
Fiber optic receiver sensitivity:
min: -31.0 dBm
max: -17.0 dBm
Link budget:
12.0 dB
NDM-FTX-SC5-01(x)
1310 nm single mode
Fiber optic transmitter power:
min: -19.0 dBm
max: -14.0 dBm
Fiber optic receiver sensitivity:
min: -31.0 dBm
max: -7.5 dBm
Link budget:
12.0 dB
NDM-FTX-SC20-01(x)
1310 nm single mode
Fiber optic transmitter power:
min: -15.0 dBm
max: -8.0 dBm
Fiber optic receiver sensitivity:
min: -31.0 dBm
max: 0.0 dBm
Link budget:
16.0 dB
NDM-FTX-SB201-01(x)
1310 TX/1550 RX nm single mode
single stand
Fiber optic transmitter power:
min: -14.0 dBm
max: -8.0 dBm
Fiber optic receiver sensitivity:
min: -32.0 dBm
max: 0.0 dBm
Link budget:
18.0 dB
Cable Specifications
Copper cable
10BASE-T UTP Category 3, 4, 5 or higher
100Base-TX UTP Category 5 or higher
Gauge:
24 to 22AWG
Attenuation:
22.0 dB /100m @ 100 MHz
• Straight-through MDI twisted-pair cable must be used.
• Shielded STP or unshielded UTP twisted-pair cable may be used.
• Pins 1 and 2, 3 and 6 are the two active pairs in an Ethernet network.
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white and white/blue, orange/white and white/orange, etc.)
• DO NOT use flat or silver satin wire.
1
2
3
6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #2
1
2
3
6
[email protected] -- Click the “Transition Now” link for live Web chat.
5
Technical Specifications
For models
NDM-FTX
-xxxxx-01 and
NDM-FTX
-xxxxx-01(L)
Standards:
IEEE 802.3
Expansion bus standard:
PCI 2.1, 2.2
Data rate:
10/100Mpbs twisted pair media
100Mbps fiber media
LED:
LINK/ACT (on the bracket)
ON = communication link; flashing = activity on link
FDX (full duplex link); ON = full duplex link
Drivers:
• NetWare Server 4.1x, 5.x
• Netware DOS Client ODI
• Windows 95, 98, 2000, 2003, XP, NT4.0
• Linux
Boot server support:
Novell RPL Boot ROM; PXE Boot ROM
PCB dimensions:
2.5” W x 5.9” D x 0.85” H
(63.5 mm W x 149.9 mm D x 21.6 mm H)
Weight:
3 oz. (91g) approximate
Power consumption:
1.0A @ +5VDC
MTBF
198,853 hours (Bellcore7 V5.0)
Operating temp
0°C to 50°C (32°F to 122°F)
Storage temp:
-25°C to 85°C (-13°F to 185°F)
Humidity:
5% to 90%, non-condensing
Altitude:
0 to 10,000 feet
Warranty:
Lifetime
WARNING: Visible and invisible laser radiation when open: DO NOT stare into
the beam or view directly with optical instruments. Failure to observe this warning
could result in damage to your vision or blindness.
CAUTION: Use of controls, adjustments, or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
The information in this manual is subject to change without further notice.
Fiber cable -- continued
NDM-FTX-SB202-01(x)
1550 TX/1310 RX nm single mode
single stand
Fiber optic transmitter power:
min: -14.0 dBm
max: -8.0 dBm
Fiber optic receiver sensitivity:
min: -32.0 dBm
max: 0.0 dBm
Link budget:
18.0 dB
The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC-
825/CDRH standard and comply with 21CRF1040.10 and 21CRF1040.11.