beautypg.com

Cable specifications, Technical specifications, Fiber cable – Milan Technology NDM-FTX-XX-01 User Manual

Page 3: Copper cable, Fiber cable -- continued

background image

NDM-FTX Series Fast Ethernet Dual Media NIC

4

Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours

The physical characteristics must meet or exceed the IEEE 802.3 specification.

Fiber cable

Bit error rate:

<10-9

Single mode fiber (recommended):

9 µm

Multimode fiber (recommended):

62.5/125 µm

Multimode fiber (optional):

100/140, 85/140, 50/125 µm

NDM-FTX-ST-01(x), NDM-FTX-SC-01(x), NDM-FTX-MT-01(x) 1300 nm multimode
Fiber optic transmitter power:

min: -19.0 dBm

max: -14.0 dBm

Fiber optic receiver sensitivity:

min: -31.0 dBm

max: -17.0 dBm

Link budget:

12.0 dB

NDM-FTX-SC5-01(x)

1310 nm single mode

Fiber optic transmitter power:

min: -19.0 dBm

max: -14.0 dBm

Fiber optic receiver sensitivity:

min: -31.0 dBm

max: -7.5 dBm

Link budget:

12.0 dB

NDM-FTX-SC20-01(x)

1310 nm single mode

Fiber optic transmitter power:

min: -15.0 dBm

max: -8.0 dBm

Fiber optic receiver sensitivity:

min: -31.0 dBm

max: 0.0 dBm

Link budget:

16.0 dB

NDM-FTX-SB201-01(x)

1310 TX/1550 RX nm single mode
single stand

Fiber optic transmitter power:

min: -14.0 dBm

max: -8.0 dBm

Fiber optic receiver sensitivity:

min: -32.0 dBm

max: 0.0 dBm

Link budget:

18.0 dB

Cable Specifications

Copper cable

10BASE-T UTP Category 3, 4, 5 or higher
100Base-TX UTP Category 5 or higher
Gauge:

24 to 22AWG

Attenuation:

22.0 dB /100m @ 100 MHz

• Straight-through MDI twisted-pair cable must be used.
• Shielded STP or unshielded UTP twisted-pair cable may be used.
• Pins 1 and 2, 3 and 6 are the two active pairs in an Ethernet network.
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:

(e.g., blue/white and white/blue, orange/white and white/orange, etc.)

• DO NOT use flat or silver satin wire.

1
2

3
6

Straight-Through Cable

Twisted Pair #1

Twisted Pair #2

1
2

3
6

[email protected] -- Click the “Transition Now” link for live Web chat.

5

Technical Specifications

For models

NDM-FTX

-xxxxx-01 and

NDM-FTX

-xxxxx-01(L)

Standards:

IEEE 802.3

Expansion bus standard:

PCI 2.1, 2.2

Data rate:

10/100Mpbs twisted pair media
100Mbps fiber media

LED:

LINK/ACT (on the bracket)
ON = communication link; flashing = activity on link
FDX (full duplex link); ON = full duplex link

Drivers:

• NetWare Server 4.1x, 5.x
• Netware DOS Client ODI
• Windows 95, 98, 2000, 2003, XP, NT4.0
• Linux

Boot server support:

Novell RPL Boot ROM; PXE Boot ROM

PCB dimensions:

2.5” W x 5.9” D x 0.85” H
(63.5 mm W x 149.9 mm D x 21.6 mm H)

Weight:

3 oz. (91g) approximate

Power consumption:

1.0A @ +5VDC

MTBF

198,853 hours (Bellcore7 V5.0)

Operating temp

0°C to 50°C (32°F to 122°F)

Storage temp:

-25°C to 85°C (-13°F to 185°F)

Humidity:

5% to 90%, non-condensing

Altitude:

0 to 10,000 feet

Warranty:

Lifetime

WARNING: Visible and invisible laser radiation when open: DO NOT stare into
the beam or view directly with optical instruments. Failure to observe this warning
could result in damage to your vision or blindness.

CAUTION: Use of controls, adjustments, or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.

The information in this manual is subject to change without further notice.

Fiber cable -- continued

NDM-FTX-SB202-01(x)

1550 TX/1310 RX nm single mode
single stand

Fiber optic transmitter power:

min: -14.0 dBm

max: -8.0 dBm

Fiber optic receiver sensitivity:

min: -32.0 dBm

max: 0.0 dBm

Link budget:

18.0 dB

The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC-
825/CDRH standard and comply with 21CRF1040.10 and 21CRF1040.11.