beautypg.com

Installation – Milan Technology NDM-FTX-XX-01 User Manual

Page 2

background image

Installation

Checklist

Before installing the NDM-FTX, verify that the package contains the following
items:
• NDM-FTX Board
• LAN Driver CD

Please notify your sales representative if any item is missing or damaged.

Description

The NDM-FTX module has a bootable ROM socket (ROM chip sold separately).
The two LED indicators, LINK/ACT and FDX located on the bracket, show
network/board link, activities, collision, and full-duplex statuses. See Figure 1.

NDM-FTX module installation

CAUTION: Wear a grounding strap and observe electrostatic discharge
precautions when installing the NDM-FTX module. Failure to observe this caution
could result in damage or failure of the NDM-FTX module.

To install the NDM-FTX module, do the following:

Important: Install the NDM-FTX module in a “master slot” only.

1.

Locate a master slot on the PC workstation or file server.

2.

Remove the cover from the PC workstation or file server—keep all screws.

3.

Remove and keep the screws holding the cover over the installation slot.

4.

Carefully slide the NDM-FTX module into the “master slot,” aligning the
module with the slot guides.

NDM-FTX Series Fast Ethernet Dual Media NIC

2

Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours

Figure 1: LEDs and Boot ROM Socket

Install the NDM-FTX module -- continued

5.

Ensure that the module is firmly seated in the slot.

6.

Use the screws from step “3” to secure the module to the workstation or
file server housing.

NDM-FTX PCI module configuration

For motherboards with automatic PCI configuration:

No specific setup is needed.

You can enter the system BIOS setup menu to view or specify the interrupt
(INT) line of the PCI slots.

For motherboards with bus master and interrupt jumpers:

Enable bus master operation in a selected PCI slot and select an INT
request line (IRQ) level, using the appropriate motherboard jumper.

Enable I/O on the NDM-FTX, PCI slot.

PCI bus system and configuration

Ensure that the PCI machine supports master slots, INT multiple sharing
and timing compatibility.

DO NOT install NDM-FTX in PCI slave slots. Please refer to your PCI
system manual and select the appropriate configuration settings.

When installing multiple NDM-FTX boards in a server station, you should
correctly configure the IRQ settings of the PCI slot.

Up to four NDM-FTX modules can be installed in a PCI file server
running NetWare operating system.

NDM-FTX server modules share the same INT line with the driver
supporting multiple INT services at a time. The IRQ of each NDM-FTX
module should not conflict with other boards.

Operation in full or half-duplex mode is configured by LAN driver
options. The operating mode should match the working status of the
remote link device.

Use EMM386 version 4.49 or higher, and install both DOS and EMM386
from the same DOS package to avoid software problems.

[email protected] -- Click the “Transition Now” link for a live Web Chat.

3