3. Open the shutoff valve in the supply line. The valve is open when the handle is parallel to
the gas pipe.
4. Test all connections by brushing on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leak found.
Connect Vent
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to
existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust
outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a
4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible gas line.
4. Once the exhaust vent connection is made, remove the corner posts and cardboard.
Level Dryer
Check the levelness of the dryer. Check levelness first side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs
up or down and check again for levelness.
Reverse Door Swing
You can change your door swing from a right-side opening to a left-side opening, if desired.
1. Place a towel or soft cloth on top of the dryer or work space to protect the surface.
Remove the door assembly
1. Remove the 4 screws that hold the door hinge on the front panel of the dryer.
2. Lay the door assembly on a flat, protected surface with the inside (inner door assembly)
facing up.
3. Remove the 6 Phillips head screws to release the outer door assembly from the inner door
assembly, as indicated below. See illustration. It is important that you remove only the
6 indicated screws.
4. Lift the inner door assembly off the outer door assembly.
A. Closed valve
B. Open valve
A
B
A. Dryer front panel
B. Door assembly
A