beautypg.com

Specifications, English – Memorex MVR4042 User Manual

Page 25

background image

25

ENGLISH

Remote control does not work.

It is not aimed at the remote sensor.

Distance too far or too much light in

the room.

There is an obstacle in the path of

the beam.

The batteries are weak.

The +, – polarity of the batteries are

not inserted correctly.

The TV/VCR function is in the VCR

mode.

Aim it at the remote sensor.

Operate within 15 feet (5 meters)

reduce the light in the room.

Clear the path of the beam.

Replace the batteries.

Insert correctly.

Set to TV, or turn off the VCR power

button.

6

6

6

TV programs cannot be seen

using the TV selector.

6

6

SYMPTOM

CAUSE

POSSIBLE SOLUTION

PAGE

REMOTE CONTROL

Video Head:
Audio Track:

Power Source:
Power Consumption:
Tuner:

RF Channel Output:
Inputs/Outputs:

Video:

Audio:

Antenna:

4 Rotary Heads
Hi-Fi Sound - 2 Tracks
MONO Sound - 1 Track
120V, 60Hz
Approx. 9 watts
181 Channel Freq. Synthesized
VHF

2-13

UHF

14-69

CATV

14-36 (A)-(W)
37-59 (AA)-(WW)
60-85 (AAA)-(ZZZ)
86-94 (86)-(94)
95-99 (A-5)-(A-1)
100-125 (100)-(125)
01 (5A)

Channel 3 or 4, Switchable

In (RCA) 1Vp-p/

75 ohm

Out (RCA) 1Vp-p/

75 ohm

In (RCA)–8dB/50K ohm
Out (RCA)–8dB/1K ohm
UHF/VHF IN 75 ohm coaxial
UHF/VHF OUT 75 ohm coaxial

Hi-Fi Frequency Response:
Hi-Fi Dynamic Range:
F.FWD/REW Time
at 25˚C (77˚F):

Speed Search:

Dimensions:

Weight:
Remote Control:

Supplied accessories:

20Hz to 20,000Hz at SP mode
More than 90dB

F. FWD: Approx. 4minutes
and 50 seconds
REW: Approx. 2minutes and
30 seconds
(with T-120 Cassette Tape)
SP

- 3 & 5 X Normal Speed

LP

- 7 & 9 X Normal Speed

SLP - 9 & 15 X Normal Speed
14-3/16"W x 3-3/4"H x
8-7/8"D
7.1 Ibs
Infrared, Direct Access,
2 x AAA batteries (not supplied)
Remote Control
75 ohm Coaxial Cable

SPECIFICATIONS

Specifications are subject to change without notice.

FOR ADDITIONAL SET-UP OR OPERATING ASSISTANCE, PLEASE VISIT OUR WEBSITE AT

WWW.MEMOREXELECTRONICS.COM OR CONTACT CUSTOMER SERVICE AT 1-800-919-3647.

PLEASE KEEP ALL PACKAGING MATERIAL FOR AT LEAST 90 DAYS IN CASE YOU NEED TO RETURN THIS

PRODUCT TO YOUR PLACE OF PURCHASE OR MEMOREX.

FOR PARTS AND ACCESSORIES, CONTACT FOX INT'L AT 1-800-321-6993.

4F90701A/E P20-BACK

20/03/2003, 10:32

25