Command Reference List
CMD1
CMD2
LEN
01. Power ON
9FH
4EH
00H
02. Power OFF
9FH
4FH
00H
03. Input Switch Change
DFH
47H
01H
04. VOLUME Gain Data
DFH
7FH
03H
05. AUDIO Mute On
9FH
3EH
00H
06. AUDIO Mute Off
9FH
3FH
00H
07. CONTRAST Gain Data
DFH
7FH
03H
08. BRIGHT Gain Data
DFH
7FH
03H
09. SHARPNESS Gain Data
DFH
7FH
03H
10. Color Gain Data
DFH
7FH
03H
11. TINT Gain Data
DFH
7FH
03H
12. PICTURE MODE Select
DFH
0AH
01H
13. COLOR TEMP SELECT
DFH
00H
01H
14. RED Gain Data
DFH
7FH
04H
15. GREEN Gain Data
DFH
7FH
04H
16. BLUE Gain Data
DFH
7FH
04H
17. NR MODE Set
DFH
C0H
01H
18. BASS Gain Data
DFH
7FH
03H
19. TREBLE Gain Data
DFH
7FH
03H
20. BALANCE Gain Data
DFH
7FH
03H
21. SCREEN MODE Select
DFH
51H
01H
22. V. POSITION Gain Data
DFH
7FH
03H
23. H. POSITION Gain Data
DFH
7FH
03H
24. V-HEIGHT Gain Data
DFH
7FH
03H
25. H-WIDTH Gain Data
DFH
7FH
03H
26. AUTO PICTURE Select
DFH
7FH
03H
27. PHASE Gain Data
DFH
7FH
03H
28. CLOCK Gain Data
DFH
7FH
03H
29. OSM Select
DFH
58H
01H
30. OSM ADJ. Gain Data
DFH
1AH
02H
31. POWER MGT Select
DFH
1AH
02H
32. GRAY LEVEL Set
DFH
C6H
01H
33. CINEMA MODE Set
DFH
C1H
01H
34. RGB3 ADJ. Select
DFH
1AH
02H
35. LONG LIFE Set
DFH
6BH
03H
36. INVERSE Set
DFH
C7H
03H
37. SCREEN WIPER Set
DFH
C8H
04H
38. RESET
1FH
54H
00H
39. Audio Select Set
DFH
70H
02H
40. BNC SELECT
DFH
8CH
01H
41. RGB Select
DFH
8BH
01H
42. HD Select
DFH
8AH
01H
43. LANGUAGE Select
DFH
5BH
01H
44. COLOR SYSTEM Select
DFH
5CH
01H
45. FREQUENCY Request
1FH
26H
00H
46. Input MODE Request
1FH
41H
00H
47. VIDEO ADJ Request
1FH
45H
00H
48. Audio Select Request
1FH
6FH
00H
49. Failure Mode Request
1FH
3FH
00H
50. MODEL NAME Request
1FH
17H
00H
01. Power ON
Function
The external control equipment switches on the power of the plasma monitor.
Transmission Data
9FH
80H
60H
4EH
00H
CKS
ACK
The plasma monitor returns the following ACK when the power is switched on.
3FH
60H
80H
4EH
00H
CKS
NOTE: Do not set the Power ON or Power OFF command
continuously.
02. Power OFF
Function
The external control equipment switches off the power of the plasma monitor.
Transmission Data
9FH
80H
60H
4FH
00H
CKS
ACK
The plasma monitor returns the following ACK when the power is switched off.
3FH
60H
80H
4FH
00H
CKS
NOTE: Do not set the Power ON or Power OFF command
continuously.
03. Input Switch Change
Function
The external control equipment switches the input of the plasma monitor.
Transmission Data
DFH
80H
60H
47H
01H
DATA00
CKS
DATA00: Input Select
01H: Video1
02H: Video2
03H: Video3
05H: HD (HD1 or DTV or DTV1)
06H: HD2 (DTV2)
07H: RGB1/PC1
08H: RGB2/PC2
0CH: RGB3/PC3
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH
60H
80H
47H
00H
CKS