Operating Temperature *
32°–120° F (0°–50° C) ambient under closed conditions
UL Listed at 40°C
Humidity Range
25–85% (non-condensing)
Storage Temperature
14°– 185° F (-10° to +85° C)
Power Requirement
9 to 12Vdc @ 650mA
Power Supply
Listed ITE power supply, marked “LPS” or “Class II”,
Requirement:
output rated: 9 to 12Vdc, 650mA
Dimensions
6.2" wide × 1.4” high x 9.0" deep (15.8 cm × 3.6 cm x 22.9 cm)
Weight
2 lbs. (0.9 kg)
Limited Warranty 2
years
Certifications
CE Mark
EMC: FCC Part 15 Class B, EN 55024
Safety: cUL, EN 60950, UL 60950
Telecom: CS03, FCC Part 68, TBR21
Intelligent Features
Plug and Play; remote configuration for centralized setup and
management; pass-through and fixed callback security; AT command
compatible; autodial, redial, repeat dial; pulse or tone dial; dial pauses;
auto answer; caller ID; adaptive line probing; automatic symbol and
carrier frequency during start-up, retrain, and rate renegotiation; DTMF
detection; call status display, auto-parity and data rate selection;
keyboard- and front panel-controlled modem options; monitor and LCD
displays for modem options; non-volatile memory; storage of up to four
command strings or telephone numbers of up to 40 characters each.
*
UL Listed @ 40° C. Limited by power supply. UL Certification does not apply or extend to an
ambient above 40° C and has not been evaluated by UL for ambient greater than 40° C.