beautypg.com

Ms2221 / ms2222 scanner design specifications, Ms2221/ms2222 scanner design specifications, Ms2221 – Metrologic Instruments StratosS MS2222 User Manual

Page 9: Ms2222

background image

5

I

NTRODUCTION

MS2221

/

MS2222

S

CANNER

D

ESIGN

S

PECIFICATIONS

Design Specifications

Operational

Light Source: VLD 650 nm

Peak Laser Power: <1.5 mW

Maximum IR LED Output: 50

μW per IEC 60825-1 measurement procedure

Horizontal Depth of Field: 0 mm - 152 mm (0”- 6”) for 0.33 mm (13 mil) Bar Code

Vertical Depth of Field: 0 mm - 216 mm (0”- 8.5”) for 0.33 mm (13 mil) Bar Code

Scan Speed: 5400 Scan Lines per Second

No. of Scan Lines: 54 (38 Horizontal / 16 Vertical)

Motor Speed: 6000 / 6000 RPM (Horizontal / Vertical )

Min Bar Width: 0.127 mm (5.0 mil)

Scan Zone: 360°

Decode Capability: All Standard 1-D Bar Codes, RSS-14, RSS-Expanded, and RSS-14 Limited Bar Codes

System Interfaces: RS232, Aux RS232, IBM468x/469x, USB, and OCIA

Print Contrast: 35% Minimum Reflectance Difference

No. Characters Read: Up to 80 data characters. Maximum number will vary based on symbology and density.

Beeper Operation: 7 Tones or No Beep; 3 Volume Settings

Blue Laser ON, Ready to Scan

Indicators (LED):

White Good Read, Decoding

Mechanical

MS2221 L x W x H: 399 mm (15.7") Length

292 mm (11.5") Width

130 mm (5.12") Tower Height

MS2222 L x W x H: 353 mm (13.9") Length

292 mm (11.5") Width

130 mm (5.12") Tower Height

Depth (Below Counter): 100 mm (3.9"), All Models

Weight (with Platter): MS2222, 5.98 kg (13.20 lbs.)

MS2221, 9.28 kg (20.5 lbs.)

Electrical

Voltage Supply: 2A @ +5.2V / 1A @ +12V

Power: Operating, 11.9 Watts

Standby, 3.25 Watts

Current: Operating, 1.5A @ 5.2V / 0.3A @ 12V

Standby, .44A @ 5.2V / 0.08A @ 12V

Current Limits on Integrated

Scale and/or Scale Display:

Do not exceed maximum current of 12V @ 0.7A / 5V @ 0.2A

DC Transformers: Class II; 5.2VDC @ 2A; 12VDC @ 1A

For Regulatory Compliance Information refer to pages 54 - 56.

Environmental

Operating Temperature: 0°C to 40°C (32°F to 104°F)

IP Rating: IP 55

Light Levels: 4842 Lux (450 footcandles)

Storage Temperature: -40°C to 60°C (-40°F to 140°F)

Humidity: 5% to 95% Relative Humidity, Non-Condensing

Contaminants: Sealed to resist airborne particulate contaminants.

Ventilation: None

Required

Specifications are subject to change without notice.

This manual is related to the following products: