Ms2221 / ms2222 scanner design specifications, Ms2221/ms2222 scanner design specifications, Ms2221 – Metrologic Instruments StratosS MS2222 User Manual
Page 9: Ms2222
5
I
NTRODUCTION
MS2221
/
MS2222
S
CANNER
D
ESIGN
S
PECIFICATIONS
Design Specifications
Operational
Light Source: VLD 650 nm
Peak Laser Power: <1.5 mW
Maximum IR LED Output: 50
μW per IEC 60825-1 measurement procedure
Horizontal Depth of Field: 0 mm - 152 mm (0”- 6”) for 0.33 mm (13 mil) Bar Code
Vertical Depth of Field: 0 mm - 216 mm (0”- 8.5”) for 0.33 mm (13 mil) Bar Code
Scan Speed: 5400 Scan Lines per Second
No. of Scan Lines: 54 (38 Horizontal / 16 Vertical)
Motor Speed: 6000 / 6000 RPM (Horizontal / Vertical )
Min Bar Width: 0.127 mm (5.0 mil)
Scan Zone: 360°
Decode Capability: All Standard 1-D Bar Codes, RSS-14, RSS-Expanded, and RSS-14 Limited Bar Codes
System Interfaces: RS232, Aux RS232, IBM468x/469x, USB, and OCIA
Print Contrast: 35% Minimum Reflectance Difference
No. Characters Read: Up to 80 data characters. Maximum number will vary based on symbology and density.
Beeper Operation: 7 Tones or No Beep; 3 Volume Settings
Blue Laser ON, Ready to Scan
Indicators (LED):
White Good Read, Decoding
Mechanical
MS2221 L x W x H: 399 mm (15.7") Length
292 mm (11.5") Width
130 mm (5.12") Tower Height
MS2222 L x W x H: 353 mm (13.9") Length
292 mm (11.5") Width
130 mm (5.12") Tower Height
Depth (Below Counter): 100 mm (3.9"), All Models
Weight (with Platter): MS2222, 5.98 kg (13.20 lbs.)
MS2221, 9.28 kg (20.5 lbs.)
Electrical
Voltage Supply: 2A @ +5.2V / 1A @ +12V
Power: Operating, 11.9 Watts
Standby, 3.25 Watts
Current: Operating, 1.5A @ 5.2V / 0.3A @ 12V
Standby, .44A @ 5.2V / 0.08A @ 12V
Current Limits on Integrated
Scale and/or Scale Display:
Do not exceed maximum current of 12V @ 0.7A / 5V @ 0.2A
DC Transformers: Class II; 5.2VDC @ 2A; 12VDC @ 1A
For Regulatory Compliance Information refer to pages 54 - 56.
Environmental
Operating Temperature: 0°C to 40°C (32°F to 104°F)
IP Rating: IP 55
Light Levels: 4842 Lux (450 footcandles)
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% Relative Humidity, Non-Condensing
Contaminants: Sealed to resist airborne particulate contaminants.
Ventilation: None
Required
Specifications are subject to change without notice.