Specifications

*

The values given in the table for the noise level reflect the levels measured at a position 1.5 meters immediately below the unit in an anechoic
chamber.

*

The noise at the air outlets is the values at a 45° angle, 1.5 meters in front of the unit.

*

The above values apply during Lossnay ventilation when the fan speed is set to high speed.

*

The values for 150 and 200 type main unit outlet noise show in the case of 1 supply air duct.

Model

name

Voltage (V)

Line

frequency

(Hz)

Current (A)

Power

consumption

(W)

Static

pressure

Air volume

Noise (dB(A))

Exchange efficiency (%)

Weight

(kg)

Air

outlets

Below

the unit

(m /h)

3

(L/S)

Temperature

Enthalpy

Heating Cooling

1-Phase

220 - 240

LGH-

15RX

4

50

0.29-0.31

63-73

150

42

77

60

70

64.5

17

1-Phase

220 - 240

LGH-

25RX

4

50

0.39-0.40

85-96

250

69

78

50

70

65

21

1-Phase

220 - 240

LGH-

35RX

4

50

0.71-0.71

154-167

350

97

79

70

70

68

30

1-Phase

220 - 240

LGH-

50RX

4

50

0.89-0.90

193-214

500 139

77

60

67.5

64.5

33

1-Phase

220 - 240

LGH-

80RX

4

50

1.60-1.60

340-370

800 222

78

100

71

67

61

1000

1-Phase

220 - 240

LGH-

150RX

4

50

3.10-3.10

670-730

1500 417

79

100

72

68

35.5-36.5

124

1-Phase

220 - 240

LGH-

200RX

4

50

(1mmH

2

O = 9.80665Pa)

4.20-4.20

910-980

2000 556

79

90

71

67

140

6.1

5.1

7.1

6.1

10.2

10.2

1-Phase

220 - 240

LGH-

100RX

4

50

2.00-2.00

440-475

278

79

100

71

67

69

10.2

9.2

(mmH

2

O) (Pa)

60Hz : Invalid in EU

60

0.33-0.35

72-84

150

42

77

70

8.2 80

64.5

17

60

0.45-0.47

98-112

250

69

78

70

6.1 60

65

21

60

0.83-0.87

180-207

350

97

79

70

5.1 50

68

30

60

1.05-1.10

231-262

500 139

77

67.5

6.1 60

64.5

33

60

3.80-3.90

820-935

1500 417

79

72

12.2 120

68

124

30-31.5

33-34

35-37

37.5-39.5

43-44

44-45

45.5-46.5

45-46

31-32.5

33.5-34.5

34-36

36.5-39

43.5-44.5

24-25

25-26

28-30

29.5-31.5

32-33

37-38

34-35

25-26

25.5-26.5

27-29

28.5-31

1-Phase

220 - 240

LGH-

65RX

4

50

1.30-1.30

270-300

650 181

76

50

68

64.5

46

5.1

60

1.50-1.60

320-370

650 181

76

68

7.1 70

64.5

46

40.5-41

40.5-41

32.5-33

32.5-33

60

2.60-2.70

565-635

1000 278

79

71

11.2 110

67

69

45-47

34-36

60

1.90-2.00

405-465

800 222

78

71

12.2 120

67

61

42-43.5

31-32.5

35-36

60

5.30-5.40

1155-1295 2000 556

79

71

10.2 100

67

140

45-47

36.5-38.5

Consult with your dealer about the after-sales services provided for this
Lossnay product.

After-sales servicing

Assembly after maintenance

1. Bearing in mind the following points, assemble the parts following the

sequence for their removal in reverse.

Attach the air filters to the magic tape on the Lossnay core(s).

Arrange the Lossnay core with the air filter side downward.

2. Press the filter button on the remote controller (PZ-41SLB-E) two

times in succession.
(This clears the Lossnay’s operating time cumulative data.)

Maintenance (Continued)

If you hear strange sounds, if no air is blown out or if some other
trouble occurs, switch off the power and contact your dealer.
Consult with your dealer concerning the cost of inspection or
repair work.

Relevant button

FILTER

(Press twice)

FILTER

Relevant display items

This manual is related to the following products: