Primary/Secondary setup continued from previous page.

All equipment must be connected before power-up. After both units complete the
power-up diagnostics, the operator will need to program the primary unit with the
MetroSet Program provided.

Additional Equipment needed:

Primary/Secondary Cable [

MLPN

52-52707]

To avoid potential problems, do not power up the scanner until the
communication cable is secured to the host.

1. Turn off the host system.

2. Connect

the

communications cable to
the HoloTrak

®

primary

scanner and to the host.

3. Connect

the

Primary/Secondary cable
to the primary scanner and
the secondary scanner.

4. Check the AC input

requirements of the power
supplies for both scanners
to make sure the voltages
match the AC outlets.

5. Connect the power

supplies to the scanners.

6. Plug the power supplies

into the AC outlets to
supply power to the both
scanners.

7. Power up the host system.

Caution:

To maintain compliance with applicable standards, all circuits connected to the scanner must meet
the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.

To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power
source should meet applicable performance requirements for a limited power source.