beautypg.com

Oil service, Oil change, Air cleaner service – MTD 08M User Manual

Page 19

background image

19

s

ectiOn

10 — e

ngine

M

aintenance

Oil Service

Check oil level regularly.

Be sure correct oil level is maintained. Check every five

hours or daily before starting engine. See oil checking

procedure in the Operation section.

Oil Change

IMPORTANT: Be sure to check engine on a level surface with the

engine stopped. Drain the oil while the engine is still warm to

assure rapid and complete draining.

Remove all fuel from tank by running engine until it stops

1.

from lack of fuel.
Remove drain plug and allow oil to drain into a suitable

2.

container. See Fig. 10-1.

WARNING:

Before tipping engine or equipment to

drain oil, drain fuel from tank by running engine

until fuel tank is empty.

Reinstall the drain plug and tighten it securely.

3.

Refill with the recommended oil (see Operation section)

4.

and check the oil level. See Fig. 10-1.
Reinstall the oil fill cap securely.

5.
IMPORTANT: Used motor oil may cause skin cancer if repeatedly

left in contact with the skin for prolonged periods. Although this

is unlikely unless you handle used oil on a daily basis, it is still

advisable to thoroughly wash your hands with soap and water as

soon as possible after handling used oil.
NOTE: Please dispose of used motor oil in a manner that is

compatible with the environment. We suggest you take it in a

sealed container to your local service station for reclamation. Do

not throw it in the trash or pour it on the ground.

Oil Fill Cap

Drain

Plug

Level

Figure 10-1

Paper Element

Foam Element

Figure 10-2

Air Cleaner Service

Paper filters cannot be cleaned and must be replaced once a year

or every 100 operating hours; more often if used in extremely

dusty conditions.

WARNING:

Never use gasoline or low flash point

solvents for cleaning the air cleaner element. A fire

or explosion could result.

IMPORTANT: Never run the engine without the air cleaner. Rapid

engine wear will result.

Remove the wing bolt and the air cleaner cover. Remove

1.

the elements and separate them. See Fig. 10-2. Replace

paper element when dirty or damaged. Clean foam

element or replace when damaged.

To clean foam element, separate it from the paper element

2.

and wash in liquid detergent and water. Allow to dry

thoroughly before using. Do not oil the foam element.